1050-H111 and 1050-O are two conditions of the same aluminum grade, 1050: H111 (slightly strain hardened) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1050-O is the stronger of the two: yield strength 30 MPa (4.35 ksi) against 25 MPa (3.63 ksi) for 1050-H111, about 20% more. 1050-O is the more ductile: elongation 38% versus 30% for 1050-H111, and 1050-H111 is harder (20 HB vs 19 HB).

1050-OChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1050-H111 vs 1050-O: properties

1050-H1111050-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

75 MPa10.9 ksi
78 MPa11.3 ksi

Yield Strength (0.2% offset)

25 MPa3.6 ksi
30 MPa4.4 ksi

Elongation at Break

30%
38%

Shear Strength

50 MPa7.3 ksi
52 MPa7.5 ksi

Fatigue Strength (Endurance Limit)

28 MPa4.1 ksi
30 MPa4.4 ksi

Hardness, Brinell

20 HB
19 HB

Hardness, Vickers

21 HV
33 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 231 W/m·K133 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 61.6 % IACS · Electrical Resistivity 2.8×10⁻⁸ Ω·m1.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

79 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

24%
25%

Formability (cold)

96 / 100
100 / 100

Same in both: Weldability 95 / 100 · Brazeability / Solderability 85 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1050

1050-H111 vs 1050-O — frequently asked

Is 1050-O stronger than 1050-H111?

Yes. 1050-O has a typical yield strength of 30 MPa (4.35 ksi) against 25 MPa (3.63 ksi) for 1050-H111 — about 20% more. Tensile strength is 78 MPa (11.3 ksi) vs 75 MPa (10.9 ksi).

Which condition does FabDigit quote by default, H111 or O?

H14 is the default 1050 condition in the FabDigit quote flow (neither H111 nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1050-H111 over 1050-O?

Pick 1050-O when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1050-H111 and 1050-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.