FabDigitFabDigit

Aluminum 1050-H111 vs 1050-H14

Aluminum · 1050 temper comparison

1050-H111 and 1050-H14 are two conditions of the same aluminum grade, 1050: H111 (slightly strain hardened) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 1050-H14 is the stronger of the two: yield strength 90 MPa (13.1 ksi) against 25 MPa (3.63 ksi) for 1050-H111, about 3.6 times as much; tensile strength follows at 110 MPa (16 ksi) vs 75 MPa (10.9 ksi). In exchange, 1050-H111 is the more ductile: elongation 30% versus 5% for 1050-H14, and 1050-H14 is harder (30 HB vs 20 HB). 1050-H111 runs hotter in service (200°C vs 150°C continuous).

1050-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1050-H14Choose it when strength drives the design.

1050-H111 vs 1050-H14: properties

1050-H1111050-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

75 MPa10.9 ksi
110 MPa16 ksi

Yield Strength (0.2% offset)

25 MPa3.6 ksi
90 MPa13.1 ksi

Elongation at Break

30%
5%

Shear Strength

50 MPa7.3 ksi
70 MPa10.2 ksi

Fatigue Strength (Endurance Limit)

28 MPa4.1 ksi
42 MPa6.1 ksi

Hardness, Brinell

20 HB
30 HB

Hardness, Vickers

21 HV
33 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

231 W/m·K133 BTU/hr·ft·°F
229 W/m·K132 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.6 % IACS
61 % IACS

Electrical Resistivity

2.8×10⁻⁸ Ω·m1.1 µΩ·in
2.83×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

79 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

24%
30%

Weldability

95 / 100
92 / 100

Formability (cold)

96 / 100
85 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1050

1050-H111 vs 1050-H14 — frequently asked

Is 1050-H14 stronger than 1050-H111?

Yes. 1050-H14 has a typical yield strength of 90 MPa (13.1 ksi) against 25 MPa (3.63 ksi) for 1050-H111 — about 3.6 times as much. Tensile strength is 110 MPa (16 ksi) vs 75 MPa (10.9 ksi).

Which condition does FabDigit quote by default, H111 or H14?

H14 is the default 1050 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1050-H111 or 1050-H14?

1050-H14, by a small margin. Both rate poor for machinability — 30/100 against 24/100 for 1050-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1050-H111 and 1050-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.