FabDigitFabDigit

Aluminum 1050-H14 vs 1050-O

Aluminum · 1050 temper comparison

1050-H14 and 1050-O are two conditions of the same aluminum grade, 1050: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1050-H14 is the stronger of the two: yield strength 90 MPa (13.1 ksi) against 30 MPa (4.35 ksi) for 1050-O, about 3.0 times as much; tensile strength follows at 110 MPa (16 ksi) vs 78 MPa (11.3 ksi). In exchange, 1050-O is the more ductile: elongation 38% versus 5% for 1050-H14, and 1050-H14 is harder (30 HB vs 19 HB). 1050-O runs hotter in service (200°C vs 150°C continuous). On the shop floor, 1050-H14 machines more easily (30 vs 20 out of 100).

1050-H14Choose it when strength drives the design, or when the part is machined in volume.

1050-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1050-H14 vs 1050-O: properties

1050-H141050-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
78 MPa11.3 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
30 MPa4.4 ksi

Elongation at Break

5%
38%

Shear Strength

70 MPa10.2 ksi
52 MPa7.5 ksi

Fatigue Strength (Endurance Limit)

42 MPa6.1 ksi
30 MPa4.4 ksi

Hardness, Brinell

30 HB
19 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Hardness, Vickers 33 HV

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

229 W/m·K132 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61 % IACS
61.6 % IACS

Electrical Resistivity

2.83×10⁻⁸ Ω·m1.11 µΩ·in
2.8×10⁻⁸ Ω·m1.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
25%

Weldability

92 / 100
95 / 100

Formability (cold)

85 / 100
100 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1050

1050-H14 vs 1050-O — frequently asked

Is 1050-H14 stronger than 1050-O?

Yes. 1050-H14 has a typical yield strength of 90 MPa (13.1 ksi) against 30 MPa (4.35 ksi) for 1050-O — about 3.0 times as much. Tensile strength is 110 MPa (16 ksi) vs 78 MPa (11.3 ksi).

Which condition does FabDigit quote by default, H14 or O?

H14 is the default 1050 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1050-H14 or 1050-O?

1050-H14, by a small margin. Both rate poor for machinability — 30/100 against 20/100 for 1050-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1050-H14 and 1050-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.