FabDigitFabDigit

Aluminum 1050-H111 vs 1050-H112

Aluminum · 1050 temper comparison

1050-H111 and 1050-H112 are two conditions of the same aluminum grade, 1050: H111 (slightly strain hardened) versus H112 (strain hardened from hot working only). The chemistry is identical, so every difference below comes from the condition. 1050-H112 is the stronger of the two: yield strength 40 MPa (5.8 ksi) against 25 MPa (3.63 ksi) for 1050-H111, about 60% more; tensile strength follows at 85 MPa (12.3 ksi) vs 75 MPa (10.9 ksi). In exchange, 1050-H111 is the more ductile: elongation 30% versus 22% for 1050-H112, and 1050-H112 is harder (23 HB vs 20 HB). 1050-H111 runs hotter in service (200°C vs 180°C continuous).

1050-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1050-H112Choose it when strength drives the design.

1050-H111 vs 1050-H112: properties

1050-H1111050-H112

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

75 MPa10.9 ksi
85 MPa12.3 ksi

Yield Strength (0.2% offset)

25 MPa3.6 ksi
40 MPa5.8 ksi

Elongation at Break

30%
22%

Shear Strength

50 MPa7.3 ksi
55 MPa8 ksi

Fatigue Strength (Endurance Limit)

28 MPa4.1 ksi
32 MPa4.6 ksi

Hardness, Brinell

20 HB
23 HB

Hardness, Vickers

21 HV
25 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

231 W/m·K133 BTU/hr·ft·°F
230 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
180°C356 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.6 % IACS
61.3 % IACS

Electrical Resistivity

2.8×10⁻⁸ Ω·m1.1 µΩ·in
2.81×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

79 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
27 / 100

Machinability Rating (AISI 1212 = 100 %)

24%
27%

Weldability

95 / 100
94 / 100

Formability (cold)

96 / 100
88 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1050

1050-H111 vs 1050-H112 — frequently asked

Is 1050-H112 stronger than 1050-H111?

Yes. 1050-H112 has a typical yield strength of 40 MPa (5.8 ksi) against 25 MPa (3.63 ksi) for 1050-H111 — about 60% more. Tensile strength is 85 MPa (12.3 ksi) vs 75 MPa (10.9 ksi).

Which condition does FabDigit quote by default, H111 or H112?

H14 is the default 1050 condition in the FabDigit quote flow (neither H111 nor H112). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1050-H111 over 1050-H112?

Pick 1050-H111 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1050-H112 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1050-H111 and 1050-H112 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.