FabDigitFabDigit

Titanium ERTi-15 vs ERTi-5

Titanium · grade comparison

Titanium ERTi-15 and ERTi-5 are both titanium grades. ERTi-5 is the stronger of the two: yield strength 895 MPa (130 ksi) against 815 MPa (118 ksi) for ERTi-15, about 10% more; tensile strength follows at 965 MPa (140 ksi) vs 880 MPa (128 ksi). In exchange, ERTi-15 is the more ductile: elongation 11% versus 8% for ERTi-5. ERTi-15 runs hotter in service (480°C vs 350°C continuous) and ERTi-15 conducts heat better (7.8 W/m·K vs 6.7 W/m·K). On the shop floor, ERTi-15 welds better (excellent vs very good).

ERTi-15Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

ERTi-5Choose it when strength drives the design.

ERTi-15 vs ERTi-5: properties

ERTi-15ERTi-5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

110 GPa16 Msi
113 GPa16.4 Msi

Poisson's Ratio

0.31
0.34

Tensile Strength (Ultimate)

880 MPa128 ksi
965 MPa140 ksi

Yield Strength (0.2% offset)

815 MPa118 ksi
895 MPa130 ksi

Elongation at Break

11%
8%

Reduction in Area

25%
18%

Compressive Strength

840 MPa122 ksi
970 MPa141 ksi

Shear Strength

550 MPa79.8 ksi
580 MPa84.1 ksi

Fatigue Strength (Endurance Limit)

430 MPa62.4 ksi
450 MPa65.3 ksi

Fracture Toughness (K_IC)

65 MPa·√m59.2 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
15 J11.1 ft·lbf

Hardness, Brinell

325 HB
330 HB

Hardness, Rockwell C

35 HRC
34 HRC

Hardness, Vickers

335 HV
345 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 110 GPa16 Msi

Physical

Density and transition temperatures.

Density

4.48 g/cm³0.16 lb/in³
4.43 g/cm³0.16 lb/in³

Melting Point (Solidus)

1,590°C2,894 °F
1,604°C2,919 °F

Liquidus Temperature

1,650°C3,002 °F
1,660°C3,020 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

7.8 W/m·K4.5 BTU/hr·ft·°F
6.7 W/m·K3.9 BTU/hr·ft·°F

Specific Heat Capacity

500 J/kg·K0.12 BTU/lb·°F
526 J/kg·K0.13 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

9.4 µm/m·K5.2 µin/in·°F
8.7 µm/m·K4.8 µin/in·°F

Latent Heat of Fusion

390 J/g168 BTU/lb
365 J/g157 BTU/lb

Max Service Temperature (continuous)

480°C896 °F
350°C662 °F

Min Service Temperature

-253°C-423 °F
-196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

1.1 % IACS
1 % IACS

Electrical Resistivity

1.57×10⁻⁶ Ω·m61.8 µΩ·in
1.7×10⁻⁶ Ω·m66.9 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.12 V
-0.1 V

Corrosion Resistance

90 / 100
88 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
22%

Weldability

85 / 100
70 / 100

Formability (cold)

35 / 100
30 / 100

Brazeability / Solderability

40 / 100
35 / 100

Castability

—
45 / 100

Same in both: Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

42 kg CO₂/kg
40 kg CO₂/kg

Embodied Water

800 L/kg95.9 gal/lb
500 L/kg59.9 gal/lb

Typical Recycled Content

20%
15%

Same in both: Embodied Energy (primary production) 650 MJ/kg279,450 BTU/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

196 kN·m/kg
218 kN·m/kg

Specific Stiffness (E / density)

24.6 MN·m/kg
25.5 MN·m/kg

Modulus of Resilience

3,019 kJ/m³
3,544 kJ/m³

Thermal Diffusivity

3.5 mm²/s
2.9 mm²/s

Same in both: Thermal Shock Resistance Index 7

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleERTi-5ERTi-15

Manufacturing and finishing

CapabilityERTi-15ERTi-5
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

Both take the same 1 finish: Plasma Spray.

ERTi-15 vs ERTi-5 — frequently asked

Is ERTi-5 stronger than ERTi-15?

Yes. ERTi-5 has a typical yield strength of 895 MPa (130 ksi) against 815 MPa (118 ksi) for ERTi-15 — about 10% more. Tensile strength is 965 MPa (140 ksi) vs 880 MPa (128 ksi).

Which is cheaper, ERTi-15 or ERTi-5?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, ERTi-15 or ERTi-5?

ERTi-15. Its weldability rates excellent (85/100) against very good (70/100) for ERTi-5.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ERTi-15 and ERTi-5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.