FabDigitFabDigit

Titanium C-1 vs C-4

Titanium · grade comparison

Titanium C-1 and C-4 are both titanium grades. C-4 is the stronger of the two: yield strength 530 MPa (76.9 ksi) against 210 MPa (30.5 ksi) for C-1, about 152% more; tensile strength follows at 620 MPa (89.9 ksi) vs 300 MPa (43.5 ksi). In exchange, C-1 is the more ductile: elongation 20% versus 12% for C-4, and C-4 is harder (265 HB vs 120 HB). C-1 conducts electricity better (3.6 % IACS vs 2.9 % IACS). On the shop floor, C-1 machines more easily (fair vs poor).

C-1Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

C-4Choose it when strength drives the design.

C-1 vs C-4: properties

C-1C-4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

103 GPa14.9 Msi
104 GPa15.1 Msi

Bulk Modulus

108 GPa15.7 Msi
110 GPa16 Msi

Tensile Strength (Ultimate)

300 MPa43.5 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
530 MPa76.9 ksi

Elongation at Break

20%
12%

Reduction in Area

30%
20%

Compressive Strength

220 MPa31.9 ksi
560 MPa81.2 ksi

Shear Strength

210 MPa30.5 ksi
430 MPa62.4 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
240 MPa34.8 ksi

Fracture Toughness (K_IC)

75 MPa·√m68.3 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

120 HB
265 HB

Hardness, Rockwell B

65 HRB
—

Hardness, Vickers

130 HV
280 HV

Hardness, Rockwell C

—
26 HRC

Same in both: Shear Modulus 45 GPa6.5 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 4.51 g/cm³0.16 lb/in³ · Melting Point (Solidus) 1,660°C3,020 °F · Liquidus Temperature 1,670°C3,038 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

17 W/m·K9.8 BTU/hr·ft·°F
17.2 W/m·K9.9 BTU/hr·ft·°F

Specific Heat Capacity

523 J/kg·K0.12 BTU/lb·°F
544 J/kg·K0.13 BTU/lb·°F

Latent Heat of Fusion

325 J/g140 BTU/lb
320 J/g138 BTU/lb

Min Service Temperature

-250°C-418 °F
-196°C-321 °F

Same in both: Thermal Expansion (CTE, 20–100 °C) 8.6 µm/m·K4.8 µin/in·°F · Max Service Temperature (continuous) 300°C572 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.6 % IACS
2.9 % IACS

Electrical Resistivity

4.8×10⁻⁷ Ω·m18.9 µΩ·in
6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

93 / 100
92 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
30 / 100

Weldability

88 / 100
85 / 100

Formability (cold)

60 / 100
20 / 100

Castability

65 / 100
60 / 100

Polishability

70 / 100
75 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 35% · Brazeability / Solderability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

640 MJ/kg275,151 BTU/lb
650 MJ/kg279,450 BTU/lb

Embodied Carbon (primary production)

40 kg CO₂/kg
39 kg CO₂/kg

Embodied Water

700 L/kg83.9 gal/lb
900 L/kg108 gal/lb

Typical Recycled Content

30%
25%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

67 kN·m/kg
137 kN·m/kg

Specific Stiffness (E / density)

22.8 MN·m/kg
23.1 MN·m/kg

Modulus of Resilience

214 kJ/m³
1,350 kJ/m³

Thermal Diffusivity

7.2 mm²/s
7 mm²/s

Thermal Shock Resistance Index

6
12

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleC-1C-4

Manufacturing and finishing

CapabilityC-1C-4
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

Both take the same 1 finish: Plasma Spray.

C-1 vs C-4 — frequently asked

Is C-4 stronger than C-1?

Yes. C-4 has a typical yield strength of 530 MPa (76.9 ksi) against 210 MPa (30.5 ksi) for C-1 — about 152% more. Tensile strength is 620 MPa (89.9 ksi) vs 300 MPa (43.5 ksi).

Which is cheaper, C-1 or C-4?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, C-1 or C-4?

C-1. Its machinability rates fair (42/100) against poor (30/100) for C-4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C-1 and C-4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.