FabDigitFabDigit

Steel Q235D-A vs Q235D-CR

Steel · Q235D temper comparison

Q235D-A and Q235D-CR are two conditions of the same steel grade, Q235D: A (solution annealed) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. Q235D-CR is the stronger of the two: yield strength 310 MPa (45 ksi) against 240 MPa (34.8 ksi) for Q235D-A, about 29% more. In exchange, Q235D-A is the more ductile: elongation 33% versus 22% for Q235D-CR, and Q235D-CR is harder (140 HB vs 115 HB). Q235D-A runs hotter in service (350°C vs 300°C continuous).

Q235D-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Q235D-CRChoose it when strength drives the design.

Q235D-A vs Q235D-CR: properties

Q235D-AQ235D-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

206 GPa29.9 Msi
205 GPa29.7 Msi

Tensile Strength (Ultimate)

400 MPa58 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
310 MPa45 ksi

Elongation at Break

33%
22%

Reduction in Area

62%
45%

Compressive Strength

240 MPa34.8 ksi
310 MPa45 ksi

Shear Strength

250 MPa36.3 ksi
265 MPa38.4 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
185 MPa26.8 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

115 HB
140 HB

Hardness, Rockwell B

64 HRB
77 HRB

Hardness, Vickers

120 HV
147 HV

Same in both: Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
50 W/m·K28.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10.8 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
62%

Weldability

95 / 100
92 / 100

Formability (cold)

92 / 100
78 / 100

Polishability

45 / 100
55 / 100

Same in both: Brazeability / Solderability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 22%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ235D

Q235D-A vs Q235D-CR — frequently asked

Is Q235D-CR stronger than Q235D-A?

Yes. Q235D-CR has a typical yield strength of 310 MPa (45 ksi) against 240 MPa (34.8 ksi) for Q235D-A — about 29% more. Tensile strength is 420 MPa (60.9 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, A or CR?

HR is the default Q235D condition in the FabDigit quote flow (neither A nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Q235D-A over Q235D-CR?

Pick Q235D-A when the part is bent, formed or impact-loaded, or when the part sees heat. Pick Q235D-CR when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q235D-A and Q235D-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.