FabDigitFabDigit

Steel Q235D-A vs Q235D TMCP

Steel · Q235D temper comparison

Q235D-A and Q235D TMCP are two conditions of the same steel grade, Q235D: A (solution annealed) versus TMCP (thermomechanically controlled processed). The chemistry is identical, so every difference below comes from the condition. Q235D TMCP is the stronger of the two: yield strength 290 MPa (42.1 ksi) against 240 MPa (34.8 ksi) for Q235D-A, about 21% more; tensile strength follows at 450 MPa (65.3 ksi) vs 400 MPa (58 ksi). Q235D TMCP is harder — 135 HB against 115 HB for Q235D-A — which matters for wear surfaces and threads.

Q235D TMCPChoose it when strength drives the design, or when surface hardness matters.

Q235D-A vs Q235D TMCP: properties

Q235D-AQ235D TMCP

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
290 MPa42.1 ksi

Elongation at Break

33%
30%

Reduction in Area

62%
57%

Compressive Strength

240 MPa34.8 ksi
290 MPa42.1 ksi

Shear Strength

250 MPa36.3 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
200 MPa29 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
140 MPa·√m127 ksi·√in

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
120 J88.5 ft·lbf

Hardness, Brinell

115 HB
135 HB

Hardness, Rockwell B

64 HRB
74 HRB

Hardness, Vickers

120 HV
142 HV

Same in both: Elastic (Young's) Modulus 206 GPa29.9 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

52 W/m·K30 BTU/hr·ft·°F
50 W/m·K28.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 350°C662 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10.8 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
66%

Weldability

95 / 100
96 / 100

Formability (cold)

92 / 100
84 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 22%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ235D

Q235D-A vs Q235D TMCP — frequently asked

Is Q235D TMCP stronger than Q235D-A?

Yes. Q235D TMCP has a typical yield strength of 290 MPa (42.1 ksi) against 240 MPa (34.8 ksi) for Q235D-A — about 21% more. Tensile strength is 450 MPa (65.3 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, A or TMCP?

HR is the default Q235D condition in the FabDigit quote flow (neither A nor TMCP). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Q235D-A or Q235D TMCP?

Q235D TMCP, by a small margin. Both rate good for machinability — 68/100 against 62/100 for Q235D-A.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q235D-A and Q235D TMCP side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.