FabDigitFabDigit

Steel Q235D-CD vs Q235D-CR

Steel · Q235D temper comparison

Q235D-CD and Q235D-CR are two conditions of the same steel grade, Q235D: CD (cold drawn) versus CR (cold rolled). The chemistry is identical, so every difference below comes from the condition. Q235D-CD is the stronger of the two: yield strength 400 MPa (58 ksi) against 310 MPa (45 ksi) for Q235D-CR, about 29% more; tensile strength follows at 500 MPa (72.5 ksi) vs 420 MPa (60.9 ksi). In exchange, Q235D-CR is the more ductile: elongation 22% versus 14% for Q235D-CD, and Q235D-CD is harder (170 HB vs 140 HB). Q235D-CD runs hotter in service (350°C vs 300°C continuous).

Q235D-CDChoose it when strength drives the design, or when the part sees heat.

Q235D-CRChoose it when the part is bent, formed or impact-loaded.

Q235D-CD vs Q235D-CR: properties

Q235D-CDQ235D-CR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

206 GPa29.9 Msi
205 GPa29.7 Msi

Tensile Strength (Ultimate)

500 MPa72.5 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
310 MPa45 ksi

Elongation at Break

14%
22%

Compressive Strength

265 MPa38.4 ksi
310 MPa45 ksi

Shear Strength

270 MPa39.2 ksi
265 MPa38.4 ksi

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
185 MPa26.8 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
95 MPa·√m86.5 ksi·√in

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

170 HB
140 HB

Hardness, Rockwell B

87 HRB
77 HRB

Hardness, Vickers

137 HV
147 HV

Same in both: Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Reduction in Area 45%

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,495°C2,723 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Thermal Conductivity 50 W/m·K28.9 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.65 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

72%
62%

Weldability

95 / 100
92 / 100

Formability (cold)

60 / 100
78 / 100

Polishability

45 / 100
55 / 100

Same in both: Brazeability / Solderability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2.1 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 22%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleQ235D

Q235D-CD vs Q235D-CR — frequently asked

Is Q235D-CD stronger than Q235D-CR?

Yes. Q235D-CD has a typical yield strength of 400 MPa (58 ksi) against 310 MPa (45 ksi) for Q235D-CR — about 29% more. Tensile strength is 500 MPa (72.5 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, CD or CR?

HR is the default Q235D condition in the FabDigit quote flow (neither CD nor CR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Q235D-CD or Q235D-CR?

Q235D-CD. Its machinability rates very good (70/100) against good (65/100) for Q235D-CR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Q235D-CD and Q235D-CR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.