FabDigitFabDigit

Steel H41-AQ vs H41-HR

Steel · H41 temper comparison

H41-AQ and H41-HR are two conditions of the same steel grade, H41: AQ (as-quenched) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. H41-AQ is the stronger of the two: yield strength 1,650 MPa (239 ksi) against 760 MPa (110 ksi) for H41-HR, about 117% more; tensile strength follows at 1,900 MPa (276 ksi) vs 1,010 MPa (146 ksi). In exchange, H41-HR is the more ductile: elongation 11% versus 1% for H41-AQ, and H41-AQ is harder (690 HB vs 300 HB). H41-HR runs hotter in service (400°C vs 200°C continuous) and H41-HR conducts heat better (25 W/m·K vs 22 W/m·K). On the shop floor, H41-HR machines more easily (poor vs not recommended) and H41-HR welds better (poor vs not recommended).

H41-AQChoose it when strength drives the design.

H41-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

H41-AQ vs H41-HR: properties

H41-AQH41-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

215 GPa31.2 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

1,900 MPa276 ksi
1,010 MPa146 ksi

Yield Strength (0.2% offset)

1,650 MPa239 ksi
760 MPa110 ksi

Elongation at Break

1%
11%

Reduction in Area

2%
28%

Compressive Strength

3,000 MPa435 ksi
1,080 MPa157 ksi

Shear Strength

1,150 MPa167 ksi
620 MPa89.9 ksi

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

690 HB
300 HB

Hardness, Vickers

830 HV
315 HV

Same in both: Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Hardness, Rockwell B 96 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.88 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

22 W/m·K12.7 BTU/hr·ft·°F
25 W/m·K14.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
400°C752 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.4 % IACS
2.7 % IACS

Electrical Resistivity

7.2×10⁻⁷ Ω·m28.3 µΩ·in
6.4×10⁻⁷ Ω·m25.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

16 / 100
14 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

5 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

5%
28%

Weldability

5 / 100
15 / 100

Formability (cold)

2 / 100
8 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 42 MJ/kg18,057 BTU/lb · Embodied Carbon (primary production) 3.1 kg CO₂/kg · Embodied Water 85 L/kg10.2 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleH41

H41-AQ vs H41-HR — frequently asked

Is H41-AQ stronger than H41-HR?

Yes. H41-AQ has a typical yield strength of 1,650 MPa (239 ksi) against 760 MPa (110 ksi) for H41-HR — about 117% more. Tensile strength is 1,900 MPa (276 ksi) vs 1,010 MPa (146 ksi).

Which condition does FabDigit quote by default, AQ or HR?

ANN is the default H41 condition in the FabDigit quote flow (neither AQ nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, H41-AQ or H41-HR?

H41-HR. Its machinability rates poor (25/100) against not recommended (5/100) for H41-AQ; for welding the order is H41-HR first (poor, 15/100) then H41-AQ (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in H41-AQ and H41-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.