FabDigitFabDigit

Steel H25-AQ vs H25-HR

Steel · H25 temper comparison

H25-AQ and H25-HR are two conditions of the same steel grade, H25: AQ (as-quenched) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. H25-AQ is the stronger of the two: yield strength 1,600 MPa (232 ksi) against 800 MPa (116 ksi) for H25-HR, about 100% more; tensile strength follows at 1,960 MPa (284 ksi) vs 1,000 MPa (145 ksi). In exchange, H25-HR is the more ductile: elongation 12% versus 1% for H25-AQ, and H25-AQ is harder (560 HB vs 300 HB). H25-HR runs hotter in service (500°C vs 200°C continuous). On the shop floor, H25-HR machines more easily (poor vs not recommended) and H25-HR welds better (poor vs not recommended).

H25-AQChoose it when strength drives the design.

H25-HRChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

H25-AQ vs H25-HR: properties

H25-AQH25-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

213 GPa30.9 Msi
215 GPa31.2 Msi

Tensile Strength (Ultimate)

1,960 MPa284 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

1,600 MPa232 ksi
800 MPa116 ksi

Elongation at Break

1%
12%

Reduction in Area

2%
25%

Compressive Strength

2,100 MPa305 ksi
850 MPa123 ksi

Shear Strength

1,180 MPa171 ksi
610 MPa88.5 ksi

Fatigue Strength (Endurance Limit)

700 MPa102 ksi
440 MPa63.8 ksi

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

560 HB
300 HB

Hardness, Vickers

595 HV
316 HV

Same in both: Shear Modulus 83 GPa12 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 96 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.55 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,455°C2,651 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

24 W/m·K13.9 BTU/hr·ft·°F
26 W/m·K15 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
500°C932 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.3 µm/m·K6.3 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.7 % IACS
2.9 % IACS

Electrical Resistivity

6.4×10⁻⁷ Ω·m25.2 µΩ·in
6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

12 / 100
15 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

5 / 100
20 / 100

Machinability Rating (AISI 1212 = 100 %)

5%
20%

Weldability

5 / 100
15 / 100

Formability (cold)

2 / 100
8 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 70 L/kg8.4 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleH25

H25-AQ vs H25-HR — frequently asked

Is H25-AQ stronger than H25-HR?

Yes. H25-AQ has a typical yield strength of 1,600 MPa (232 ksi) against 800 MPa (116 ksi) for H25-HR — about 100% more. Tensile strength is 1,960 MPa (284 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, AQ or HR?

ANN is the default H25 condition in the FabDigit quote flow (neither AQ nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, H25-AQ or H25-HR?

H25-HR. Its machinability rates poor (20/100) against not recommended (5/100) for H25-AQ; for welding the order is H25-HR first (poor, 15/100) then H25-AQ (not recommended, 5/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in H25-AQ and H25-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.