FabDigitFabDigit

Steel E6010-AW vs E6010-SR

Steel · E6010 temper comparison

E6010-AW and E6010-SR are two conditions of the same steel grade, E6010: AW (as-welded deposit) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. E6010-AW is the stronger of the two: yield strength 400 MPa (58 ksi) against 370 MPa (53.7 ksi) for E6010-SR, about 8% more; tensile strength follows at 480 MPa (69.6 ksi) vs 455 MPa (66 ksi). E6010-AW is harder — 155 HB against 145 HB for E6010-SR — which matters for wear surfaces and threads.

E6010-AWChoose it when strength drives the design, or when surface hardness matters.

E6010-AW vs E6010-SR: properties

E6010-AWE6010-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
455 MPa66 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
370 MPa53.7 ksi

Elongation at Break

28%
31%

Shear Strength

300 MPa43.5 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
195 MPa28.3 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
100 J73.8 ft·lbf

Hardness, Brinell

155 HB
145 HB

Hardness, Rockwell B

82 HRB
78 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 79 GPa11.5 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.85 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,480°C2,696 °F · Liquidus Temperature 1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

50 W/m·K28.9 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12 µm/m·K6.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -30°C-22 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.62 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
64 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
70%

Formability (cold)

55 / 100
60 / 100

Same in both: Weldability 92 / 100 · Brazeability / Solderability 70 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 32 MJ/kg13,758 BTU/lb · Embodied Carbon (primary production) 2.4 kg CO₂/kg · Embodied Water 60 L/kg7.2 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleE6010

E6010-AW vs E6010-SR — frequently asked

Is E6010-AW stronger than E6010-SR?

Yes. E6010-AW has a typical yield strength of 400 MPa (58 ksi) against 370 MPa (53.7 ksi) for E6010-SR — about 8% more. Tensile strength is 480 MPa (69.6 ksi) vs 455 MPa (66 ksi).

Which condition does FabDigit quote by default, AW or SR?

AW is the default E6010 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose E6010-AW over E6010-SR?

Pick E6010-AW when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in E6010-AW and E6010-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.