FabDigitFabDigit

Steel A216 WCA vs GE360

Steel · grade comparison

Steel A216 WCA and GE360 are both steel grades. GE360 is the stronger of the two: yield strength 400 MPa (58 ksi) against 255 MPa (37 ksi) for A216 WCA, about 57% more; tensile strength follows at 690 MPa (100 ksi) vs 455 MPa (66 ksi). In exchange, A216 WCA is the more ductile: elongation 31% versus 12% for GE360, and GE360 is harder (195 HB vs 130 HB). On the shop floor, A216 WCA machines more easily (good vs fair) and A216 WCA welds better (excellent vs fair).

A216 WCAChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

GE360Choose it when strength drives the design.

A216 WCA vs GE360: properties

A216 WCAGE360

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
210 GPa30.5 Msi

Shear Modulus

78 GPa11.3 Msi
80 GPa11.6 Msi

Tensile Strength (Ultimate)

455 MPa66 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
400 MPa58 ksi

Elongation at Break

31%
12%

Reduction in Area

50%
25%

Compressive Strength

255 MPa37 ksi
400 MPa58 ksi

Shear Strength

285 MPa41.3 ksi
420 MPa60.9 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
290 MPa42.1 ksi

Fracture Toughness (K_IC)

90 MPa·√m81.9 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

48 J35.4 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

130 HB
195 HB

Hardness, Rockwell B

72 HRB
92 HRB

Hardness, Vickers

—
205 HV

Same in both: Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Density

7.83 g/cm³0.28 lb/in³
7.85 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,425°C2,597 °F
1,420°C2,588 °F

Liquidus Temperature

1,510°C2,750 °F
1,490°C2,714 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

11.7 µm/m·K6.5 µin/in·°F
12.3 µm/m·K6.8 µin/in·°F

Latent Heat of Fusion

247 J/g106 BTU/lb
250 J/g107 BTU/lb

Max Service Temperature (continuous)

425°C797 °F
400°C752 °F

Min Service Temperature

-29°C-20 °F
-20°C-4 °F

Same in both: Specific Heat Capacity 470 J/kg·K0.11 BTU/lb·°F

Electrical

Conductivity and insulation.

Electrical Conductivity

10 % IACS
9.5 % IACS

Electrical Resistivity

1.7×10⁻⁷ Ω·m6.69 µΩ·in
1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.65 V
-0.62 V

Corrosion Resistance

10 / 100
12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
55%

Weldability

85 / 100
50 / 100

Formability (cold)

20 / 100
15 / 100

Castability

72 / 100
65 / 100

Polishability

40 / 100
55 / 100

Same in both: Brazeability / Solderability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

26 MJ/kg11,178 BTU/lb
22 MJ/kg9,458 BTU/lb

Embodied Carbon (primary production)

2.1 kg CO₂/kg
1.9 kg CO₂/kg

Embodied Water

45 L/kg5.4 gal/lb
40 L/kg4.8 gal/lb

Same in both: Typical Recycled Content 85%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

58 kN·m/kg
88 kN·m/kg

Specific Stiffness (E / density)

25.5 MN·m/kg
26.8 MN·m/kg

Modulus of Resilience

163 kJ/m³
381 kJ/m³

Thermal Diffusivity

13.9 mm²/s
13 mm²/s

Thermal Shock Resistance Index

10
13

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA216 WCAGE360

Manufacturing and finishing

CapabilityA216 WCAGE360
Default condition——
Relative cost$$ Standard$$ Standard
Min. machined wall——
Best machined surface——

Both take the same 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

A216 WCA vs GE360 — frequently asked

Is GE360 stronger than A216 WCA?

Yes. GE360 has a typical yield strength of 400 MPa (58 ksi) against 255 MPa (37 ksi) for A216 WCA — about 57% more. Tensile strength is 690 MPa (100 ksi) vs 455 MPa (66 ksi).

Which is cheaper, A216 WCA or GE360?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, A216 WCA or GE360?

A216 WCA. Its machinability rates good (68/100) against fair (45/100) for GE360; for welding the order is A216 WCA first (excellent, 85/100) then GE360 (fair, 50/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in A216 WCA and GE360 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.