Steel · grade comparison

Steel 4620 and 5015 are both steel grades. 4620 is the stronger of the two: yield strength 360 MPa (52.2 ksi) against 285 MPa (41.3 ksi) for 5015, about 26% more; tensile strength follows at 570 MPa (82.7 ksi) vs 415 MPa (60.2 ksi). In exchange, 5015 is the more ductile: elongation 32% versus 26% for 4620, and 4620 is harder (163 HB vs 121 HB). 5015 conducts electricity better (9.5 % IACS vs 8 % IACS). On the shop floor, 5015 welds better (very good vs good) and 5015 sits in a lower cost tier (budget, $) than 4620 (standard, $$).

4620Choose it when strength drives the design.

5015Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

4620 vs 5015: properties

46205015

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

570 MPa82.7 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

360 MPa52.2 ksi
285 MPa41.3 ksi

Elongation at Break

26%
32%

Reduction in Area

55%
63%

Shear Strength

380 MPa55.1 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

85 J62.7 ft·lbf
95 J70.1 ft·lbf

Hardness, Brinell

163 HB
121 HB

Hardness, Rockwell B

84 HRB
68 HRB

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,420°C2,588 °F
1,425°C2,597 °F

Liquidus Temperature

1,500°C2,732 °F
1,510°C2,750 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Latent Heat of Fusion

250 J/g107 BTU/lb
270 J/g116 BTU/lb

Min Service Temperature

-50°C-58 °F
-40°C-40 °F

Same in both: Specific Heat Capacity 475 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Max Service Temperature (continuous) 400°C752 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8 % IACS
9.5 % IACS

Electrical Resistivity

2.2×10⁻⁷ Ω·m8.66 µΩ·in
1.8×10⁻⁷ Ω·m7.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.61 V
-0.6 V

Same in both: Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

57 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
60%

Weldability

65 / 100
78 / 100

Formability (cold)

58 / 100
74 / 100

Same in both: Brazeability / Solderability 70 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

29 MJ/kg12,468 BTU/lb
30 MJ/kg12,898 BTU/lb

Embodied Water

55 L/kg6.6 gal/lb
45 L/kg5.4 gal/lb

Same in both: Embodied Carbon (primary production) 2.2 kg CO₂/kg · Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

73 kN·m/kg
53 kN·m/kg

Modulus of Resilience

316 kJ/m³
198 kJ/m³

Thermal Diffusivity

12.3 mm²/s
12.1 mm²/s

Thermal Shock Resistance Index

11
8

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale46205015

Manufacturing and finishing

Capability46205015
CNC machiningYes—
Sheet metalYes—
Default conditionHR—
Relative cost$$ Standard$ Budget
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
E-CoatingYes—
HVOF CoatingYes—
Hot-Dip GalvanizingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

4620 vs 5015 — frequently asked

Is 4620 stronger than 5015?

Yes. 4620 has a typical yield strength of 360 MPa (52.2 ksi) against 285 MPa (41.3 ksi) for 5015 — about 26% more. Tensile strength is 570 MPa (82.7 ksi) vs 415 MPa (60.2 ksi).

Which is cheaper, 4620 or 5015?

5015 is the lower-cost material: it sits in the budget tier ($) while 4620 is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which welds better, 4620 or 5015?

5015. Its weldability rates very good (78/100) against good (65/100) for 4620.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4620 and 5015 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.