FabDigitFabDigit

Steel 45L vs A352 LCC

Steel · grade comparison

Steel 45L and A352 LCC are both steel grades. 45L is the stronger of the two: tensile strength 600 MPa (87 ksi) against 525 MPa (76.1 ksi) for A352 LCC, about 14% more. In exchange, A352 LCC is the more ductile: elongation 26% versus 12% for 45L, and 45L is harder (207 HB vs 155 HB). A352 LCC conducts electricity better (10 % IACS vs 8.5 % IACS). On the shop floor, A352 LCC welds better (very good vs poor) and 45L sits in a lower cost tier (budget, $) than A352 LCC (standard, $$).

45LChoose it when strength drives the design, or when cost is the deciding factor.

A352 LCCChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

45L vs A352 LCC: properties

45LA352 LCC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
202 GPa29.3 Msi

Shear Modulus

80 GPa11.6 Msi
79 GPa11.5 Msi

Tensile Strength (Ultimate)

600 MPa87 ksi
525 MPa76.1 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
315 MPa45.7 ksi

Elongation at Break

12%
26%

Reduction in Area

22%
45%

Compressive Strength

330 MPa47.9 ksi
320 MPa46.4 ksi

Shear Strength

360 MPa52.2 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

245 MPa35.5 ksi
230 MPa33.4 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

207 HB
155 HB

Hardness, Rockwell B

94 HRB
84 HRB

Hardness, Vickers

218 HV
—

Same in both: Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Density

7.83 g/cm³0.28 lb/in³
7.85 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,420°C2,588 °F
1,425°C2,597 °F

Liquidus Temperature

1,490°C2,714 °F
1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

48 W/m·K27.7 BTU/hr·ft·°F
50 W/m·K28.9 BTU/hr·ft·°F

Specific Heat Capacity

470 J/kg·K0.11 BTU/lb·°F
486 J/kg·K0.12 BTU/lb·°F

Max Service Temperature (continuous)

400°C752 °F
425°C797 °F

Min Service Temperature

-30°C-22 °F
-46°C-51 °F

Same in both: Thermal Expansion (CTE, 20–100 °C) 11.9 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

8.5 % IACS
10 % IACS

Electrical Resistivity

2×10⁻⁷ Ω·m7.87 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.61 V
-0.62 V

Corrosion Resistance

11 / 100
12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
63 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
72%

Weldability

30 / 100
80 / 100

Formability (cold)

15 / 100
20 / 100

Castability

70 / 100
75 / 100

Brazeability / Solderability

55 / 100
60 / 100

Polishability

55 / 100
45 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

25 MJ/kg10,748 BTU/lb
24 MJ/kg10,318 BTU/lb

Embodied Carbon (primary production)

2 kg CO₂/kg
1.9 kg CO₂/kg

Embodied Water

35 L/kg4.2 gal/lb
45 L/kg5.4 gal/lb

Typical Recycled Content

80%
85%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

77 kN·m/kg
67 kN·m/kg

Specific Stiffness (E / density)

26.2 MN·m/kg
25.7 MN·m/kg

Modulus of Resilience

266 kJ/m³
246 kJ/m³

Thermal Diffusivity

13 mm²/s
13.1 mm²/s

Thermal Shock Resistance Index

12
11

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scaleA352 LCC45L

Manufacturing and finishing

Capability45LA352 LCC
Default condition——
Relative cost$ Budget$$ Standard
Min. machined wall——
Best machined surface——

Both take the same 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

45L vs A352 LCC — frequently asked

Is 45L stronger than A352 LCC?

Yes. 45L has a typical tensile strength of 600 MPa (87 ksi) against 525 MPa (76.1 ksi) for A352 LCC — about 14% more.

Which is cheaper, 45L or A352 LCC?

45L is the lower-cost material: it sits in the budget tier ($) while A352 LCC is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, 45L or A352 LCC?

A352 LCC, by a small margin. Both rate good for machinability — 63/100 against 55/100 for 45L; for welding the order is A352 LCC first (very good, 80/100) then 45L (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 45L and A352 LCC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.