FabDigitFabDigit

Steel 4140 vs 5150

Steel · grade comparison

Steel 4140 and 5150 are both steel grades. 5150 is the stronger of the two: tensile strength 800 MPa (116 ksi) against 690 MPa (100 ksi) for 4140, about 16% more. In exchange, 4140 is the more ductile: elongation 22% versus 18% for 5150, and 5150 is harder (229 HB vs 210 HB). 4140 runs hotter in service (425°C vs 300°C continuous). On the shop floor, 4140 machines more easily (good vs fair) and 4140 welds better (fair vs poor).

4140Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5150Choose it when strength drives the design.

4140 vs 5150: properties

41405150

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
800 MPa116 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
460 MPa66.7 ksi

Elongation at Break

22%
18%

Reduction in Area

50%
42%

Compressive Strength

480 MPa69.6 ksi
460 MPa66.7 ksi

Shear Strength

420 MPa60.9 ksi
490 MPa71.1 ksi

Fatigue Strength (Endurance Limit)

345 MPa50 ksi
370 MPa53.7 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
—

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

210 HB
229 HB

Hardness, Rockwell B

94 HRB
98 HRB

Hardness, Vickers

220 HV
240 HV

Hardness, Rockwell C

—
20 HRC

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,416°C2,581 °F
1,420°C2,588 °F

Liquidus Temperature

1,483°C2,701 °F
1,465°C2,669 °F

Same in both: Density 7.85 g/cm³0.28 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

42.6 W/m·K24.6 BTU/hr·ft·°F
46 W/m·K26.6 BTU/hr·ft·°F

Specific Heat Capacity

473 J/kg·K0.11 BTU/lb·°F
470 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12.3 µm/m·K6.8 µin/in·°F
12.4 µm/m·K6.9 µin/in·°F

Max Service Temperature (continuous)

425°C797 °F
300°C572 °F

Min Service Temperature

-40°C-40 °F
-30°C-22 °F

Same in both: Latent Heat of Fusion 250 J/g107 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

7.8 % IACS
8 % IACS

Same in both: Electrical Resistivity 2.2×10⁻⁷ Ω·m8.66 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 12 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
55%

Weldability

40 / 100
25 / 100

Formability (cold)

40 / 100
35 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

32 MJ/kg13,758 BTU/lb
26 MJ/kg11,178 BTU/lb

Embodied Carbon (primary production)

2.2 kg CO₂/kg
2 kg CO₂/kg

Embodied Water

55 L/kg6.6 gal/lb
60 L/kg7.2 gal/lb

Same in both: Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

88 kN·m/kg
102 kN·m/kg

Modulus of Resilience

562 kJ/m³
516 kJ/m³

Thermal Diffusivity

11.5 mm²/s
12.5 mm²/s

Thermal Shock Resistance Index

12
14

Same in both: Specific Stiffness (E / density) 26.1 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale41405150

Manufacturing and finishing

Capability41405150
Casting & forgingYes—
Default conditionHRHR
Relative cost$$ Standard$$ Standard
Min. machined wall0.8 mm0.8 mm
Best machined surfaceRa 1.6 µmRa 1.6 µm

Both are offered for CNC machining and Sheet metal. Both take the same 38 finishes: AlCrN, AlTiN, Black Oxide, CVD Al2O3, CVD TiCN, CVD TiN, Cerakote, Chrome Plating, Copper Plating, CrN, DLC, E-Coating and 26 more.

4140 vs 5150 — frequently asked

Is 5150 stronger than 4140?

Yes. 5150 has a typical tensile strength of 800 MPa (116 ksi) against 690 MPa (100 ksi) for 4140 — about 16% more.

Which is cheaper, 4140 or 5150?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 4140 or 5150?

4140. Its machinability rates good (60/100) against fair (50/100) for 5150; for welding the order is 4140 first (fair, 40/100) then 5150 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4140 and 5150 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.