FabDigitFabDigit

Steel 18Ni(190) Aged vs 18Ni(190)-CD

Steel · 18Ni(190) temper comparison

18Ni(190) Aged and 18Ni(190)-CD are two conditions of the same steel grade, 18Ni(190): Aged (solution annealed + aged 480 °C / 3–6 h, air cool) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 18Ni(190) Aged is the stronger of the two: yield strength 1,280 MPa (186 ksi) against 1,030 MPa (149 ksi) for 18Ni(190)-CD, about 24% more; tensile strength follows at 1,330 MPa (193 ksi) vs 1,170 MPa (170 ksi). 18Ni(190) Aged is the more ductile: elongation 14% versus 10% for 18Ni(190)-CD, and 18Ni(190) Aged is harder (375 HB vs 320 HB). 18Ni(190) Aged runs hotter in service (400°C vs 300°C continuous) and 18Ni(190)-CD conducts heat better (24.5 W/m·K vs 20.9 W/m·K). On the shop floor, 18Ni(190)-CD machines more easily (45 vs 35 out of 100).

18Ni(190) AgedChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

18Ni(190)-CDChoose it when the part is machined in volume.

18Ni(190) Aged vs 18Ni(190)-CD: properties

18Ni(190) Aged18Ni(190)-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

190 GPa27.6 Msi
187 GPa27.1 Msi

Tensile Strength (Ultimate)

1,330 MPa193 ksi
1,170 MPa170 ksi

Yield Strength (0.2% offset)

1,280 MPa186 ksi
1,030 MPa149 ksi

Elongation at Break

14%
10%

Reduction in Area

66%
50%

Compressive Strength

1,310 MPa190 ksi
1,060 MPa154 ksi

Shear Strength

800 MPa116 ksi
700 MPa102 ksi

Fatigue Strength (Endurance Limit)

620 MPa89.9 ksi
520 MPa75.4 ksi

Fracture Toughness (K_IC)

155 MPa·√m141 ksi·√in
190 MPa·√m173 ksi·√in

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
95 J70.1 ft·lbf

Hardness, Brinell

375 HB
320 HB

Hardness, Rockwell C

40 HRC
34 HRC

Hardness, Vickers

395 HV
335 HV

Same in both: Shear Modulus 72 GPa10.4 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,413°C2,575 °F · Liquidus Temperature 1,454°C2,649 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

20.9 W/m·K12.1 BTU/hr·ft·°F
24.5 W/m·K14.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
300°C572 °F

Same in both: Specific Heat Capacity 452 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.1 µm/m·K5.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.8 % IACS
3 % IACS

Electrical Resistivity

4.5×10⁻⁷ Ω·m17.7 µΩ·in
5.8×10⁻⁷ Ω·m22.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V · Corrosion Resistance 25 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
45%

Weldability

85 / 100
90 / 100

Formability (cold)

20 / 100
35 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale18Ni(190)

18Ni(190) Aged vs 18Ni(190)-CD — frequently asked

Is 18Ni(190) Aged stronger than 18Ni(190)-CD?

Yes. 18Ni(190) Aged has a typical yield strength of 1,280 MPa (186 ksi) against 1,030 MPa (149 ksi) for 18Ni(190)-CD — about 24% more. Tensile strength is 1,330 MPa (193 ksi) vs 1,170 MPa (170 ksi).

Which condition does FabDigit quote by default, Aged or CD?

Aged is the default 18Ni(190) condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 18Ni(190) Aged or 18Ni(190)-CD?

18Ni(190)-CD, by a small margin. Both rate fair for machinability — 45/100 against 35/100 for 18Ni(190) Aged; for welding the order is 18Ni(190)-CD first (excellent, 90/100) then 18Ni(190) Aged (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 18Ni(190) Aged and 18Ni(190)-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.