18Ni(190)-AW and 18Ni(190)-CD are two conditions of the same steel grade, 18Ni(190): AW (as-welded deposit) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 18Ni(190)-CD is the stronger of the two: yield strength 1,030 MPa (149 ksi) against 860 MPa (125 ksi) for 18Ni(190)-AW, about 20% more; tensile strength follows at 1,170 MPa (170 ksi) vs 1,050 MPa (152 ksi). In exchange, 18Ni(190)-AW is the more ductile: elongation 12% versus 10% for 18Ni(190)-CD, and 18Ni(190)-CD is harder (320 HB vs 295 HB).

18Ni(190)-AWChoose it when the part is bent, formed or impact-loaded.

18Ni(190)-CDChoose it when strength drives the design.

18Ni(190)-AW vs 18Ni(190)-CD: properties

18Ni(190)-AW18Ni(190)-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

188 GPa27.3 Msi
187 GPa27.1 Msi

Tensile Strength (Ultimate)

1,050 MPa152 ksi
1,170 MPa170 ksi

Yield Strength (0.2% offset)

860 MPa125 ksi
1,030 MPa149 ksi

Elongation at Break

12%
10%

Reduction in Area

48%
50%

Compressive Strength

890 MPa129 ksi
1,060 MPa154 ksi

Shear Strength

650 MPa94.3 ksi
700 MPa102 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
520 MPa75.4 ksi

Fracture Toughness (K_IC)

135 MPa·√m123 ksi·√in
190 MPa·√m173 ksi·√in

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
95 J70.1 ft·lbf

Hardness, Brinell

295 HB
320 HB

Hardness, Rockwell C

31 HRC
34 HRC

Hardness, Vickers

310 HV
335 HV

Same in both: Shear Modulus 72 GPa10.4 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,413°C2,575 °F · Liquidus Temperature 1,454°C2,649 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

23.5 W/m·K13.6 BTU/hr·ft·°F
24.5 W/m·K14.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 452 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.1 µm/m·K5.6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

3.1 % IACS
3 % IACS

Electrical Resistivity

5.6×10⁻⁷ Ω·m22 µΩ·in
5.8×10⁻⁷ Ω·m22.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

22 / 100
25 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.6 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
45 / 100

Weldability

85 / 100
90 / 100

Formability (cold)

30 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 45% · Brazeability / Solderability 50 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 120 L/kg14.4 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale18Ni(190)

18Ni(190)-AW vs 18Ni(190)-CD — frequently asked

Is 18Ni(190)-CD stronger than 18Ni(190)-AW?

Yes. 18Ni(190)-CD has a typical yield strength of 1,030 MPa (149 ksi) against 860 MPa (125 ksi) for 18Ni(190)-AW — about 20% more. Tensile strength is 1,170 MPa (170 ksi) vs 1,050 MPa (152 ksi).

Which condition does FabDigit quote by default, AW or CD?

Aged is the default 18Ni(190) condition in the FabDigit quote flow (neither AW nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 18Ni(190)-AW or 18Ni(190)-CD?

18Ni(190)-CD. Its weldability rates excellent (90/100) against excellent (85/100) for 18Ni(190)-AW.