FabDigitFabDigit

Steel 1215 vs Y12

Steel · grade comparison

Steel 1215 and Y12 are both steel grades. Y12 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 250 MPa (36.3 ksi) for 1215, about 80% more; tensile strength follows at 590 MPa (85.6 ksi) vs 415 MPa (60.2 ksi). In exchange, 1215 is the more ductile: elongation 25% versus 10% for Y12, and Y12 is harder (180 HB vs 121 HB). 1215 runs hotter in service (400°C vs 350°C continuous).

1215Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Y12Choose it when strength drives the design.

1215 vs Y12: properties

1215Y12

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

415 MPa60.2 ksi
590 MPa85.6 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
450 MPa65.3 ksi

Elongation at Break

25%
10%

Reduction in Area

45%
35%

Shear Strength

290 MPa42.1 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
250 MPa36.3 ksi

Hardness, Brinell

121 HB
180 HB

Hardness, Rockwell B

70 HRB
89 HRB

Charpy V-Notch Impact (RT)

—
20 J14.8 ft·lbf

Hardness, Vickers

—
190 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Density

7.87 g/cm³0.28 lb/in³
7.85 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,420°C2,588 °F
1,495°C2,723 °F

Liquidus Temperature

1,510°C2,750 °F
1,520°C2,768 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51.9 W/m·K30 BTU/hr·ft·°F
51 W/m·K29.5 BTU/hr·ft·°F

Specific Heat Capacity

486 J/kg·K0.12 BTU/lb·°F
470 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

11.9 µm/m·K6.6 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Latent Heat of Fusion

247 J/g106 BTU/lb
270 J/g116 BTU/lb

Max Service Temperature (continuous)

400°C752 °F
350°C662 °F

Same in both: Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10.5 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.65×10⁻⁷ Ω·m6.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 8 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

120%
100%

Weldability

20 / 100
25 / 100

Formability (cold)

35 / 100
30 / 100

Brazeability / Solderability

55 / 100
60 / 100

Polishability

40 / 100
45 / 100

Same in both: Machinability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

26 MJ/kg11,178 BTU/lb
25 MJ/kg10,748 BTU/lb

Typical Recycled Content

35%
30%

Same in both: Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

53 kN·m/kg
75 kN·m/kg

Specific Stiffness (E / density)

25.4 MN·m/kg
25.5 MN·m/kg

Modulus of Resilience

156 kJ/m³
506 kJ/m³

Thermal Diffusivity

13.6 mm²/s
13.8 mm²/s

Thermal Shock Resistance Index

9
13

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1215Y12

Manufacturing and finishing

Capability1215Y12
CNC machiningYes—
Default conditionHR—
Relative cost$ Budget$ Budget
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
E-CoatingYes—
HVOF CoatingYes—
Hot-Dip GalvanizingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

1215 vs Y12 — frequently asked

Is Y12 stronger than 1215?

Yes. Y12 has a typical yield strength of 450 MPa (65.3 ksi) against 250 MPa (36.3 ksi) for 1215 — about 80% more. Tensile strength is 590 MPa (85.6 ksi) vs 415 MPa (60.2 ksi).

Which is cheaper, 1215 or Y12?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, 1215 or Y12?

Y12. Its weldability rates poor (25/100) against poor (20/100) for 1215.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1215 and Y12 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.