FabDigitFabDigit

Steel 1117 vs Y20

Steel · grade comparison

Steel 1117 and Y20 are both steel grades. Y20 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 235 MPa (34.1 ksi) for 1117, about 91% more; tensile strength follows at 570 MPa (82.7 ksi) vs 425 MPa (61.6 ksi). In exchange, 1117 is the more ductile: elongation 33% versus 12% for Y20, and Y20 is harder (180 HB vs 121 HB). On the shop floor, 1117 welds better (50 vs 35 out of 100).

1117Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

Y20Choose it when strength drives the design.

1117 vs Y20: properties

1117Y20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
205 GPa29.7 Msi

Tensile Strength (Ultimate)

425 MPa61.6 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

235 MPa34.1 ksi
450 MPa65.3 ksi

Elongation at Break

33%
12%

Reduction in Area

58%
42%

Shear Strength

320 MPa46.4 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

50 J36.9 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

121 HB
180 HB

Hardness, Rockwell B

68 HRB
88 HRB

Compressive Strength

—
450 MPa65.3 ksi

Hardness, Vickers

—
190 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Density

7.87 g/cm³0.28 lb/in³
7.85 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,420°C2,588 °F
1,425°C2,597 °F

Liquidus Temperature

1,500°C2,732 °F
1,505°C2,741 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

51 W/m·K29.5 BTU/hr·ft·°F
50 W/m·K28.9 BTU/hr·ft·°F

Specific Heat Capacity

470 J/kg·K0.11 BTU/lb·°F
480 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

11.7 µm/m·K6.5 µin/in·°F
11.9 µm/m·K6.6 µin/in·°F

Same in both: Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.8 % IACS
10 % IACS

Electrical Resistivity

1.6×10⁻⁷ Ω·m6.3 µΩ·in
1.7×10⁻⁷ Ω·m6.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.61 V
-0.62 V

Corrosion Resistance

10 / 100
9 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
78 / 100

Machinability Rating (AISI 1212 = 100 %)

91%
78%

Weldability

50 / 100
35 / 100

Formability (cold)

60 / 100
45 / 100

Brazeability / Solderability

65 / 100
60 / 100

Castability

—
40 / 100

Same in both: Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

45 L/kg5.4 gal/lb
50 L/kg6 gal/lb

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

54 kN·m/kg
73 kN·m/kg

Specific Stiffness (E / density)

25.4 MN·m/kg
26.1 MN·m/kg

Modulus of Resilience

138 kJ/m³
494 kJ/m³

Thermal Diffusivity

13.8 mm²/s
13.3 mm²/s

Thermal Shock Resistance Index

9
12

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1117Y20

Manufacturing and finishing

Capability1117Y20
CNC machiningYes—
Default conditionHR—
Relative cost$ Budget$ Budget
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
AlCrNYes—
AlTiNYes—
Black OxideYes—
CVD Al2O3Yes—
CVD TiCNYes—
CVD TiNYes—
CerakoteYes—
Chrome PlatingYes—
CrNYes—
DLCYes—
E-CoatingYes—
HVOF CoatingYes—
Hot-Dip GalvanizingYes—
MoS2Yes—
Multilayer CVDYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

1117 vs Y20 — frequently asked

Is Y20 stronger than 1117?

Yes. Y20 has a typical yield strength of 450 MPa (65.3 ksi) against 235 MPa (34.1 ksi) for 1117 — about 91% more. Tensile strength is 570 MPa (82.7 ksi) vs 425 MPa (61.6 ksi).

Which is cheaper, 1117 or Y20?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 1117 or Y20?

Y20, by a small margin. Both rate very good for machinability — 78/100 against 70/100 for 1117; for welding the order is 1117 first (fair, 50/100) then Y20 (fair, 35/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1117 and Y20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.