Steel · grade comparison

Steel 1115 and 1117 are both steel grades. 1115 is the stronger of the two: yield strength 410 MPa (59.5 ksi) against 235 MPa (34.1 ksi) for 1117, about 74% more; tensile strength follows at 480 MPa (69.6 ksi) vs 425 MPa (61.6 ksi). In exchange, 1117 is the more ductile: elongation 33% versus 15% for 1115, and 1115 is harder (143 HB vs 121 HB). On the shop floor, 1115 machines more easily (80 vs 70 out of 100) and 1117 welds better (50 vs 40 out of 100).

1115Choose it when strength drives the design, or when the part is machined in volume.

1117Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

1115 vs 1117: properties

11151117

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
425 MPa61.6 ksi

Yield Strength (0.2% offset)

410 MPa59.5 ksi
235 MPa34.1 ksi

Elongation at Break

15%
33%

Reduction in Area

40%
58%

Shear Strength

290 MPa42.1 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
200 MPa29 ksi

Fracture Toughness (K_IC)

80 MPa·√m72.8 ksi·√in
—

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

143 HB
121 HB

Hardness, Rockwell B

78 HRB
68 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Liquidus Temperature

1,510°C2,750 °F
1,500°C2,732 °F

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F

Thermal

How each material carries heat and how hot it can run.

Specific Heat Capacity

486 J/kg·K0.12 BTU/lb·°F
470 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

11.9 µm/m·K6.6 µin/in·°F
11.7 µm/m·K6.5 µin/in·°F

Same in both: Thermal Conductivity 51 W/m·K29.5 BTU/hr·ft·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.6×10⁻⁷ Ω·m6.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.62 V
-0.61 V

Same in both: Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

80 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
91%

Weldability

40 / 100
50 / 100

Formability (cold)

45 / 100
60 / 100

Brazeability / Solderability

70 / 100
65 / 100

Same in both: Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 1.9 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

61 kN·m/kg
54 kN·m/kg

Modulus of Resilience

420 kJ/m³
138 kJ/m³

Thermal Diffusivity

13.3 mm²/s
13.8 mm²/s

Thermal Shock Resistance Index

10
9

Same in both: Specific Stiffness (E / density) 25.4 MN·m/kg

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale11171115

Manufacturing and finishing

Capability11151117
CNC machining—Yes
Default condition—HR
Relative cost$ Budget$ Budget
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
AlCrN—Yes
AlTiN—Yes
Black Oxide—Yes
CVD Al2O3—Yes
CVD TiCN—Yes
CVD TiN—Yes
Cerakote—Yes
Chrome Plating—Yes
CrN—Yes
DLC—Yes
E-Coating—Yes
HVOF Coating—Yes
Hot-Dip Galvanizing—Yes
MoS2—Yes
Multilayer CVD—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes

They share 9 finishes: Copper Plating, Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Manganese Phosphate, Plasma Spray, Silver Plating, Zinc Phosphate.

1115 vs 1117 — frequently asked

Is 1115 stronger than 1117?

Yes. 1115 has a typical yield strength of 410 MPa (59.5 ksi) against 235 MPa (34.1 ksi) for 1117 — about 74% more. Tensile strength is 480 MPa (69.6 ksi) vs 425 MPa (61.6 ksi).

Which is cheaper, 1115 or 1117?

Both sit in the same relative cost tier ($, budget); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, 1115 or 1117?

1115, by a small margin. Both rate very good for machinability — 80/100 against 70/100 for 1117; for welding the order is 1117 first (fair, 50/100) then 1115 (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1115 and 1117 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.