FabDigitFabDigit

Steel 1019-HR vs 1019-N

Steel · 1019 temper comparison

1019-HR and 1019-N are two conditions of the same steel grade, 1019: HR (hot rolled) versus N (normalized). The chemistry is identical, so every difference below comes from the condition. 1019-N is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 225 MPa (32.6 ksi) for 1019-HR, about 11% more; tensile strength follows at 430 MPa (62.4 ksi) vs 407 MPa (59 ksi). 1019-N is the more ductile: elongation 30% versus 25% for 1019-HR, and 1019-N is harder (138 HV vs 122 HV).

1019-NChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1019-HR vs 1019-N: properties

1019-HR1019-N

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

407 MPa59 ksi
430 MPa62.4 ksi

Yield Strength (0.2% offset)

225 MPa32.6 ksi
250 MPa36.3 ksi

Elongation at Break

25%
30%

Reduction in Area

50%
60%

Shear Strength

255 MPa37 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
235 MPa34.1 ksi

Charpy V-Notch Impact (RT)

70 J51.6 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

116 HB
121 HB

Hardness, Rockwell B

65 HRB
68 HRB

Hardness, Vickers

122 HV
138 HV

Same in both: Elastic (Young's) Modulus 205 GPa29.7 Msi · Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Compressive Strength 395 MPa57.3 ksi · Fracture Toughness (K_IC) 90 MPa·√m81.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.87 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,515°C2,759 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

425°C797 °F
400°C752 °F

Same in both: Thermal Conductivity 51.9 W/m·K30 BTU/hr·ft·°F · Specific Heat Capacity 486 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.7 µm/m·K6.5 µin/in·°F · Latent Heat of Fusion 250 J/g107 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10.8 % IACS · Electrical Resistivity 1.59×10⁻⁷ Ω·m6.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.61 V · Corrosion Resistance 10 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
65%

Weldability

93 / 100
90 / 100

Formability (cold)

82 / 100
80 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 80 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 25 MJ/kg10,748 BTU/lb · Embodied Carbon (primary production) 2 kg CO₂/kg · Embodied Water 45 L/kg5.4 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0002,0007.588.5Density (g/cm³)Yield strength (MPa) — log scale1019

1019-HR vs 1019-N — frequently asked

Is 1019-N stronger than 1019-HR?

Yes. 1019-N has a typical yield strength of 250 MPa (36.3 ksi) against 225 MPa (32.6 ksi) for 1019-HR — about 11% more. Tensile strength is 430 MPa (62.4 ksi) vs 407 MPa (59 ksi).

Which condition does FabDigit quote by default, HR or N?

CD is the default 1019 condition in the FabDigit quote flow (neither HR nor N). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1019-HR over 1019-N?

Pick 1019-N when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1019-HR and 1019-N side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.