FabDigitFabDigit

Stainless Steel SUH1-A vs SUH1-QT

Stainless Steel · SUH1 temper comparison

SUH1-A and SUH1-QT are two conditions of the same stainless steel grade, SUH1: A (solution annealed) versus QT (quenched and tempered). The chemistry is identical, so every difference below comes from the condition. SUH1-QT is the stronger of the two: yield strength 760 MPa (110 ksi) against 450 MPa (65.3 ksi) for SUH1-A, about 69% more; tensile strength follows at 1,000 MPa (145 ksi) vs 760 MPa (110 ksi). In exchange, SUH1-A is the more ductile: elongation 22% versus 18% for SUH1-QT, and SUH1-QT is harder (295 HB vs 230 HB). SUH1-QT runs hotter in service (750°C vs 600°C continuous). On the shop floor, SUH1-A machines more easily (45 vs 35 out of 100).

SUH1-AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

SUH1-QTChoose it when strength drives the design, or when the part sees heat.

SUH1-A vs SUH1-QT: properties

SUH1-ASUH1-QT

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

760 MPa110 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
760 MPa110 ksi

Elongation at Break

22%
18%

Reduction in Area

50%
45%

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
420 MPa60.9 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
15 J11.1 ft·lbf

Hardness, Brinell

230 HB
295 HB

Hardness, Rockwell C

20 HRC
31 HRC

Hardness, Vickers

240 HV
310 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 165 GPa23.9 Msi · Poisson's Ratio 0.29 · Compressive Strength 780 MPa113 ksi · Shear Strength 620 MPa89.9 ksi · Fracture Toughness (K_IC) 32 MPa·√m29.1 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,420°C2,588 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

600°C1,112 °F
750°C1,382 °F

Same in both: Thermal Conductivity 21 W/m·K12.1 BTU/hr·ft·°F · Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11 µm/m·K6.1 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.45 V · Corrosion Resistance 42 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
35%

Formability (cold)

28 / 100
18 / 100

Same in both: Weldability 22 / 100 · Castability 40 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 110 L/kg13.2 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleSUH1

SUH1-A vs SUH1-QT — frequently asked

Is SUH1-QT stronger than SUH1-A?

Yes. SUH1-QT has a typical yield strength of 760 MPa (110 ksi) against 450 MPa (65.3 ksi) for SUH1-A — about 69% more. Tensile strength is 1,000 MPa (145 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, A or QT?

QT is the default SUH1 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, SUH1-A or SUH1-QT?

SUH1-A, by a small margin. Both rate fair for machinability — 45/100 against 35/100 for SUH1-QT.

Ready to make it?

Upload a CAD file and FabDigit prices the part in SUH1-A and SUH1-QT side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.