FabDigitFabDigit

Stainless Steel Almar 362-H1050 vs Almar 362-H900

Stainless Steel · Almar 362 temper comparison

Almar 362-H1050 and Almar 362-H900 are two conditions of the same stainless steel grade, Almar 362: H1050 (aged 565 °C / 4 h) versus H900 (aged 482 °C (900 °F) for 1 h, peak hardness). The chemistry is identical, so every difference below comes from the condition. Almar 362-H900 is the stronger of the two: yield strength 1,205 MPa (175 ksi) against 930 MPa (135 ksi) for Almar 362-H1050, about 30% more; tensile strength follows at 1,275 MPa (185 ksi) vs 1,035 MPa (150 ksi). In exchange, Almar 362-H1050 is the more ductile: elongation 18% versus 15% for Almar 362-H900, and Almar 362-H900 is harder (375 HB vs 302 HB). Almar 362-H1050 runs hotter in service (510°C vs 425°C continuous).

Almar 362-H1050Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Almar 362-H900Choose it when strength drives the design.

Almar 362-H1050 vs Almar 362-H900: properties

Almar 362-H1050Almar 362-H900

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,035 MPa150 ksi
1,275 MPa185 ksi

Yield Strength (0.2% offset)

930 MPa135 ksi
1,205 MPa175 ksi

Elongation at Break

18%
15%

Reduction in Area

62%
55%

Shear Strength

620 MPa89.9 ksi
760 MPa110 ksi

Fatigue Strength (Endurance Limit)

520 MPa75.4 ksi
650 MPa94.3 ksi

Charpy V-Notch Impact (RT)

58 J42.8 ft·lbf
34 J25.1 ft·lbf

Hardness, Brinell

302 HB
375 HB

Hardness, Rockwell C

32 HRC
40 HRC

Hardness, Vickers

320 HV
400 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Compressive Strength 1,240 MPa180 ksi · Fracture Toughness (K_IC) 80 MPa·√m72.8 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 7.76 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

510°C950 °F
425°C797 °F

Same in both: Thermal Conductivity 16.5 W/m·K9.5 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.8 µm/m·K6 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

57 / 100
50 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

38%
30%

Same in both: Machinability 32 / 100 · Weldability 60 / 100 · Formability (cold) 15 / 100 · Brazeability / Solderability 45 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleAlmar 362

Almar 362-H1050 vs Almar 362-H900 — frequently asked

Is Almar 362-H900 stronger than Almar 362-H1050?

Yes. Almar 362-H900 has a typical yield strength of 1,205 MPa (175 ksi) against 930 MPa (135 ksi) for Almar 362-H1050 — about 30% more. Tensile strength is 1,275 MPa (185 ksi) vs 1,035 MPa (150 ksi).

Which condition does FabDigit quote by default, H1050 or H900?

H900 is the default Almar 362 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Almar 362-H1050 over Almar 362-H900?

Pick Almar 362-H1050 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick Almar 362-H900 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Almar 362-H1050 and Almar 362-H900 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.