FabDigitFabDigit

Stainless Steel 95Kh18 QT-52-54HRC vs 95Kh18 QT-55-57HRC

Stainless Steel · 95Kh18 temper comparison

95Kh18 QT-52-54HRC and 95Kh18 QT-55-57HRC are two conditions of the same stainless steel grade, 95Kh18: QT-52-54HRC versus QT-55-57HRC. The chemistry is identical, so every difference below comes from the condition. 95Kh18 QT-55-57HRC is the stronger of the two: yield strength 1,750 MPa (254 ksi) against 1,550 MPa (225 ksi) for 95Kh18 QT-52-54HRC, about 13% more; tensile strength follows at 1,880 MPa (273 ksi) vs 1,750 MPa (254 ksi). In exchange, 95Kh18 QT-52-54HRC is the more ductile: elongation 4% versus 3% for 95Kh18 QT-55-57HRC, and 95Kh18 QT-55-57HRC is harder (56 HRC vs 53 HRC). 95Kh18 QT-52-54HRC runs hotter in service (480°C vs 320°C continuous).

95Kh18 QT-52-54HRCChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

95Kh18 QT-55-57HRCChoose it when strength drives the design.

95Kh18 QT-52-54HRC vs 95Kh18 QT-55-57HRC: properties

95Kh18 QT-52-54HRC95Kh18 QT-55-57HRC

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,750 MPa254 ksi
1,880 MPa273 ksi

Yield Strength (0.2% offset)

1,550 MPa225 ksi
1,750 MPa254 ksi

Elongation at Break

4%
3%

Reduction in Area

8%
6%

Compressive Strength

1,750 MPa254 ksi
2,000 MPa290 ksi

Shear Strength

470 MPa68.2 ksi
1,150 MPa167 ksi

Fatigue Strength (Endurance Limit)

650 MPa94.3 ksi
720 MPa104 ksi

Charpy V-Notch Impact (RT)

10 J7.4 ft·lbf
9 J6.6 ft·lbf

Hardness, Rockwell C

53 HRC
56 HRC

Hardness, Vickers

570 HV
630 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Hardness, Brinell 255 HB · Hardness, Rockwell B 100 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,370°C2,498 °F · Liquidus Temperature 1,480°C2,696 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

480°C896 °F
320°C608 °F

Same in both: Thermal Conductivity 24 W/m·K13.9 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.2 µm/m·K5.7 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -40°C-40 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

30 / 100
40 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

12 / 100
8 / 100

Machinability Rating (AISI 1212 = 100 %)

10%
8%

Formability (cold)

25 / 100
2 / 100

Polishability

88 / 100
90 / 100

Same in both: Weldability 10 / 100 · Brazeability / Solderability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 130 L/kg15.6 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale95Kh18

95Kh18 QT-52-54HRC vs 95Kh18 QT-55-57HRC — frequently asked

Is 95Kh18 QT-55-57HRC stronger than 95Kh18 QT-52-54HRC?

Yes. 95Kh18 QT-55-57HRC has a typical yield strength of 1,750 MPa (254 ksi) against 1,550 MPa (225 ksi) for 95Kh18 QT-52-54HRC — about 13% more. Tensile strength is 1,880 MPa (273 ksi) vs 1,750 MPa (254 ksi).

Which condition does FabDigit quote by default, QT-52-54HRC or QT-55-57HRC?

ANN is the default 95Kh18 condition in the FabDigit quote flow (neither QT-52-54HRC nor QT-55-57HRC). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 95Kh18 QT-52-54HRC over 95Kh18 QT-55-57HRC?

Pick 95Kh18 QT-52-54HRC when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 95Kh18 QT-55-57HRC when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 95Kh18 QT-52-54HRC and 95Kh18 QT-55-57HRC side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.