FabDigitFabDigit

Stainless Steel 430FSe-CD vs 430FSe-HR

Stainless Steel · 430FSe temper comparison

430FSe-CD and 430FSe-HR are two conditions of the same stainless steel grade, 430FSe: CD (cold drawn) versus HR (hot rolled). The chemistry is identical, so every difference below comes from the condition. 430FSe-CD is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 345 MPa (50 ksi) for 430FSe-HR, about 59% more; tensile strength follows at 655 MPa (95 ksi) vs 550 MPa (79.8 ksi). In exchange, 430FSe-HR is the more ductile: elongation 22% versus 15% for 430FSe-CD, and 430FSe-CD is harder (215 HB vs 185 HB).

430FSe-CDChoose it when strength drives the design.

430FSe-HRChoose it when the part is bent, formed or impact-loaded.

430FSe-CD vs 430FSe-HR: properties

430FSe-CD430FSe-HR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

655 MPa95 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
345 MPa50 ksi

Elongation at Break

15%
22%

Reduction in Area

40%
50%

Shear Strength

360 MPa52.2 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

300 MPa43.5 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

10 J7.4 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

215 HB
185 HB

Hardness, Rockwell B

95 HRB
89 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 26 W/m·K15 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.4 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 700°C1,292 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
43 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
64 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
70%

Formability (cold)

18 / 100
26 / 100

Same in both: Weldability 18 / 100 · Brazeability / Solderability 45 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale430FSe

430FSe-CD vs 430FSe-HR — frequently asked

Is 430FSe-CD stronger than 430FSe-HR?

Yes. 430FSe-CD has a typical yield strength of 550 MPa (79.8 ksi) against 345 MPa (50 ksi) for 430FSe-HR — about 59% more. Tensile strength is 655 MPa (95 ksi) vs 550 MPa (79.8 ksi).

Which condition does FabDigit quote by default, CD or HR?

A is the default 430FSe condition in the FabDigit quote flow (neither CD nor HR). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 430FSe-CD or 430FSe-HR?

430FSe-CD. Its machinability rates very good (70/100) against good (64/100) for 430FSe-HR.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 430FSe-CD and 430FSe-HR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.