FabDigitFabDigit

Stainless Steel 430FSe-A vs 430FSe-CD

Stainless Steel · 430FSe temper comparison

430FSe-A and 430FSe-CD are two conditions of the same stainless steel grade, 430FSe: A (solution annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 430FSe-CD is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 310 MPa (45 ksi) for 430FSe-A, about 77% more; tensile strength follows at 655 MPa (95 ksi) vs 520 MPa (75.4 ksi). In exchange, 430FSe-A is the more ductile: elongation 25% versus 15% for 430FSe-CD, and 430FSe-CD is harder (215 HB vs 175 HB).

430FSe-AChoose it when the part is bent, formed or impact-loaded.

430FSe-CDChoose it when strength drives the design.

430FSe-A vs 430FSe-CD: properties

430FSe-A430FSe-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

520 MPa75.4 ksi
655 MPa95 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
550 MPa79.8 ksi

Elongation at Break

25%
15%

Reduction in Area

55%
40%

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
300 MPa43.5 ksi

Charpy V-Notch Impact (RT)

15 J11.1 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

175 HB
215 HB

Hardness, Rockwell B

86 HRB
95 HRB

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Shear Strength 360 MPa52.2 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,425°C2,597 °F · Liquidus Temperature 1,510°C2,750 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 26 W/m·K15 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.4 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 700°C1,292 °F · Min Service Temperature -20°C-4 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

66 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
75%

Formability (cold)

30 / 100
18 / 100

Same in both: Weldability 18 / 100 · Brazeability / Solderability 45 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale430FSe

430FSe-A vs 430FSe-CD — frequently asked

Is 430FSe-CD stronger than 430FSe-A?

Yes. 430FSe-CD has a typical yield strength of 550 MPa (79.8 ksi) against 310 MPa (45 ksi) for 430FSe-A — about 77% more. Tensile strength is 655 MPa (95 ksi) vs 520 MPa (75.4 ksi).

Which condition does FabDigit quote by default, A or CD?

A is the default 430FSe condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 430FSe-A over 430FSe-CD?

Pick 430FSe-A when the part is bent, formed or impact-loaded. Pick 430FSe-CD when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 430FSe-A and 430FSe-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.