310HCb Annealed and 310HCb-CD are two conditions of the same stainless steel grade, 310HCb: Annealed versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 310HCb-CD is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 260 MPa (37.7 ksi) for 310HCb Annealed, about 73% more; tensile strength follows at 690 MPa (100 ksi) vs 590 MPa (85.6 ksi). In exchange, 310HCb Annealed is the more ductile: elongation 45% versus 30% for 310HCb-CD, and 310HCb-CD is harder (210 HB vs 170 HB).

310HCb AnnealedChoose it when the part is bent, formed or impact-loaded.

310HCb-CDChoose it when strength drives the design.

310HCb Annealed vs 310HCb-CD: properties

310HCb Annealed310HCb-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

590 MPa85.6 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
450 MPa65.3 ksi

Elongation at Break

45%
30%

Reduction in Area

55%
45%

Compressive Strength

260 MPa37.7 ksi
460 MPa66.7 ksi

Shear Strength

400 MPa58 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
285 MPa41.3 ksi

Fracture Toughness (K_IC)

200 MPa·√m182 ksi·√in
150 MPa·√m137 ksi·√in

Charpy V-Notch Impact (RT)

120 J88.5 ft·lbf
80 J59 ft·lbf

Hardness, Brinell

170 HB
210 HB

Hardness, Rockwell B

85 HRB
95 HRB

Hardness, Vickers

180 HV
220 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 7.98 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 14.2 W/m·K8.2 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.9 µm/m·K8.8 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 1,100°C2,012 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 7.8×10⁻⁷ Ω·m30.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
45%

Weldability

70 / 100
65 / 100

Formability (cold)

65 / 100
45 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 68 MJ/kg29,235 BTU/lb · Embodied Carbon (primary production) 5.8 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale310HCb

310HCb Annealed vs 310HCb-CD — frequently asked

Is 310HCb-CD stronger than 310HCb Annealed?

Yes. 310HCb-CD has a typical yield strength of 450 MPa (65.3 ksi) against 260 MPa (37.7 ksi) for 310HCb Annealed — about 73% more. Tensile strength is 690 MPa (100 ksi) vs 590 MPa (85.6 ksi).

Which condition does FabDigit quote by default, Annealed or CD?

Annealed is the default 310HCb condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 310HCb Annealed or 310HCb-CD?

310HCb Annealed. Its weldability rates very good (70/100) against good (65/100) for 310HCb-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 310HCb Annealed and 310HCb-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.