15-7 Mo Condition A and 15-7 Mo-TH1050 are two conditions of the same stainless steel grade, 15-7 Mo: Condition A (solution annealed) versus TH1050 (austenite conditioned at 760 °C, cooled, then aged 566 °C). The chemistry is identical, so every difference below comes from the condition. 15-7 Mo-TH1050 is the stronger of the two: yield strength 1,345 MPa (195 ksi) against 415 MPa (60.2 ksi) for 15-7 Mo Condition A, about 3.2 times as much; tensile strength follows at 1,415 MPa (205 ksi) vs 950 MPa (138 ksi). In exchange, 15-7 Mo Condition A is the more ductile: elongation 25% versus 7% for 15-7 Mo-TH1050, and 15-7 Mo-TH1050 is harder (45 HRC vs 13 HRC). On the shop floor, 15-7 Mo Condition A machines more easily (fair vs poor).
15-7 Mo Condition AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.
15-7 Mo-TH1050Choose it when strength drives the design.
15-7 Mo Condition A vs 15-7 Mo-TH1050: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all stainless steel grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
15-7 Mo Condition A15-7 Mo-TH1050
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Charpy V-Notch Impact (RT)
Hardness, Rockwell C
Hardness, Vickers
Same in both: Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Brinell 200 HB · Hardness, Rockwell B 92 HRB
Physical
Density and transition temperatures.
Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F
Thermal
How each material carries heat and how hot it can run.
Same in both: Thermal Conductivity 16 W/m·K9.2 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Max Service Temperature (continuous) 425°C797 °F · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 2.1 % IACS · Electrical Resistivity 8.3×10⁻⁷ Ω·m32.7 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Formability (cold)
Same in both: Weldability 50 / 100 · Brazeability / Solderability 40 / 100 · Polishability 70 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 68 MJ/kg29,235 BTU/lb · Embodied Carbon (primary production) 5.4 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
15-7 Mo Condition A vs 15-7 Mo-TH1050 — frequently asked
Is 15-7 Mo-TH1050 stronger than 15-7 Mo Condition A?
Yes. 15-7 Mo-TH1050 has a typical yield strength of 1,345 MPa (195 ksi) against 415 MPa (60.2 ksi) for 15-7 Mo Condition A — about 3.2 times as much. Tensile strength is 1,415 MPa (205 ksi) vs 950 MPa (138 ksi).
Which condition does FabDigit quote by default, Condition A or TH1050?
Condition A is the default 15-7 Mo condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, 15-7 Mo Condition A or 15-7 Mo-TH1050?
15-7 Mo Condition A. Its machinability rates fair (45/100) against poor (28/100) for 15-7 Mo-TH1050.
Ready to make it?
Upload a CAD file and FabDigit prices the part in 15-7 Mo Condition A and 15-7 Mo-TH1050 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.