15-7 Mo-CH900 and 15-7 Mo Condition A are two conditions of the same stainless steel grade, 15-7 Mo: CH900 (condition C strip aged 482 °C) versus Condition A (solution annealed). The chemistry is identical, so every difference below comes from the condition. 15-7 Mo-CH900 is the stronger of the two: yield strength 1,655 MPa (240 ksi) against 415 MPa (60.2 ksi) for 15-7 Mo Condition A, about 4.0 times as much; tensile strength follows at 1,725 MPa (250 ksi) vs 950 MPa (138 ksi). In exchange, 15-7 Mo Condition A is the more ductile: elongation 25% versus 2% for 15-7 Mo-CH900, and 15-7 Mo-CH900 is harder (48 HRC vs 13 HRC). 15-7 Mo Condition A runs hotter in service (425°C vs 370°C continuous). On the shop floor, 15-7 Mo Condition A machines more easily (fair vs poor) and 15-7 Mo Condition A welds better (fair vs poor).

15-7 Mo-CH900Choose it when strength drives the design.

15-7 Mo Condition AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

15-7 Mo-CH900 vs 15-7 Mo Condition A: properties

15-7 Mo-CH90015-7 Mo Condition A

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Poisson's Ratio

0.28
0.29

Tensile Strength (Ultimate)

1,725 MPa250 ksi
950 MPa138 ksi

Yield Strength (0.2% offset)

1,655 MPa240 ksi
415 MPa60.2 ksi

Elongation at Break

2%
25%

Shear Strength

1,030 MPa149 ksi
600 MPa87 ksi

Fatigue Strength (Endurance Limit)

690 MPa100 ksi
340 MPa49.3 ksi

Hardness, Rockwell C

48 HRC
13 HRC

Hardness, Vickers

490 HV
210 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Reduction in Area 45% · Compressive Strength 420 MPa60.9 ksi · Charpy V-Notch Impact (RT) 90 J66.4 ft·lbf · Hardness, Brinell 200 HB · Hardness, Rockwell B 92 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

16.4 W/m·K9.5 BTU/hr·ft·°F
16 W/m·K9.2 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

11.6 µm/m·K6.4 µin/in·°F
11.5 µm/m·K6.4 µin/in·°F

Max Service Temperature (continuous)

370°C698 °F
425°C797 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.1 % IACS · Electrical Resistivity 8.3×10⁻⁷ Ω·m32.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

15%
45%

Weldability

30 / 100
50 / 100

Formability (cold)

5 / 100
60 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

56 MJ/kg24,076 BTU/lb
68 MJ/kg29,235 BTU/lb

Embodied Carbon (primary production)

3.5 kg CO₂/kg
5.4 kg CO₂/kg

Typical Recycled Content

40%
30%

Same in both: Embodied Water 200 L/kg24 gal/lb

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale15-7 Mo

15-7 Mo-CH900 vs 15-7 Mo Condition A — frequently asked

Is 15-7 Mo-CH900 stronger than 15-7 Mo Condition A?

Yes. 15-7 Mo-CH900 has a typical yield strength of 1,655 MPa (240 ksi) against 415 MPa (60.2 ksi) for 15-7 Mo Condition A — about 4.0 times as much. Tensile strength is 1,725 MPa (250 ksi) vs 950 MPa (138 ksi).

Which condition does FabDigit quote by default, CH900 or Condition A?

Condition A is the default 15-7 Mo condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 15-7 Mo-CH900 or 15-7 Mo Condition A?

15-7 Mo Condition A. Its machinability rates fair (45/100) against poor (18/100) for 15-7 Mo-CH900; for welding the order is 15-7 Mo Condition A first (fair, 50/100) then 15-7 Mo-CH900 (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 15-7 Mo-CH900 and 15-7 Mo Condition A side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.