15-7 Mo Condition A and 15-7 Mo Condition T are two conditions of the same stainless steel grade, 15-7 Mo: Condition A (solution annealed) versus Condition T (austenite conditioned at 760 °C (1400 °F), cooled to ≤16 °C). The chemistry is identical, so every difference below comes from the condition. 15-7 Mo Condition T is the stronger of the two: yield strength 760 MPa (110 ksi) against 415 MPa (60.2 ksi) for 15-7 Mo Condition A, about 83% more; tensile strength follows at 1,030 MPa (149 ksi) vs 950 MPa (138 ksi). In exchange, 15-7 Mo Condition A is the more ductile: elongation 25% versus 10% for 15-7 Mo Condition T, and 15-7 Mo Condition T is harder (300 HB vs 200 HB). On the shop floor, 15-7 Mo Condition A machines more easily (fair vs poor) and 15-7 Mo Condition A welds better (50 vs 40 out of 100).

15-7 Mo Condition AChoose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

15-7 Mo Condition TChoose it when strength drives the design.

15-7 Mo Condition A vs 15-7 Mo Condition T: properties

15-7 Mo Condition A15-7 Mo Condition T

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

950 MPa138 ksi
1,030 MPa149 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
760 MPa110 ksi

Elongation at Break

25%
10%

Reduction in Area

45%
40%

Compressive Strength

420 MPa60.9 ksi
790 MPa115 ksi

Shear Strength

600 MPa87 ksi
640 MPa92.8 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
470 MPa68.2 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

200 HB
300 HB

Hardness, Rockwell C

13 HRC
32 HRC

Hardness, Vickers

210 HV
318 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Rockwell B 92 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

16 W/m·K9.2 BTU/hr·ft·°F
16.3 W/m·K9.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

425°C797 °F
400°C752 °F

Same in both: Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

2.1 % IACS
2.2 % IACS

Electrical Resistivity

8.3×10⁻⁷ Ω·m32.7 µΩ·in
8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
35%

Weldability

50 / 100
40 / 100

Formability (cold)

60 / 100
25 / 100

Same in both: Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 68 MJ/kg29,235 BTU/lb · Embodied Carbon (primary production) 5.4 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale15-7 Mo

15-7 Mo Condition A vs 15-7 Mo Condition T — frequently asked

Is 15-7 Mo Condition T stronger than 15-7 Mo Condition A?

Yes. 15-7 Mo Condition T has a typical yield strength of 760 MPa (110 ksi) against 415 MPa (60.2 ksi) for 15-7 Mo Condition A — about 83% more. Tensile strength is 1,030 MPa (149 ksi) vs 950 MPa (138 ksi).

Which condition does FabDigit quote by default, Condition A or Condition T?

Condition A is the default 15-7 Mo condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 15-7 Mo Condition A or 15-7 Mo Condition T?

15-7 Mo Condition A. Its machinability rates fair (45/100) against poor (30/100) for 15-7 Mo Condition T; for welding the order is 15-7 Mo Condition A first (fair, 50/100) then 15-7 Mo Condition T (fair, 40/100).