FabDigitFabDigit

Stainless Steel 15-7 Mo Condition A vs 15-7 Mo-RH950

Stainless Steel · 15-7 Mo temper comparison

15-7 Mo Condition A and 15-7 Mo-RH950 are two conditions of the same stainless steel grade, 15-7 Mo: Condition A (solution annealed) versus RH950 (austenite conditioned at 954 °C, refrigerated −73 °C, aged 510 °C). The chemistry is identical, so every difference below comes from the condition. 15-7 Mo-RH950 is the stronger of the two: yield strength 1,520 MPa (220 ksi) against 415 MPa (60.2 ksi) for 15-7 Mo Condition A, about 3.7 times as much; tensile strength follows at 1,620 MPa (235 ksi) vs 950 MPa (138 ksi). In exchange, 15-7 Mo Condition A is the more ductile: elongation 25% versus 6% for 15-7 Mo-RH950, and 15-7 Mo-RH950 is harder (48 HRC vs 13 HRC). 15-7 Mo Condition A runs hotter in service (425°C vs 370°C continuous). On the shop floor, 15-7 Mo Condition A machines more easily (fair vs poor).

15-7 Mo Condition AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

15-7 Mo-RH950Choose it when strength drives the design.

15-7 Mo Condition A vs 15-7 Mo-RH950: properties

15-7 Mo Condition A15-7 Mo-RH950

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

950 MPa138 ksi
1,620 MPa235 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
1,520 MPa220 ksi

Elongation at Break

25%
6%

Reduction in Area

45%
18%

Compressive Strength

420 MPa60.9 ksi
1,550 MPa225 ksi

Shear Strength

600 MPa87 ksi
970 MPa141 ksi

Fatigue Strength (Endurance Limit)

340 MPa49.3 ksi
760 MPa110 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
13 J9.6 ft·lbf

Hardness, Rockwell C

13 HRC
48 HRC

Hardness, Vickers

210 HV
500 HV

Same in both: Elastic (Young's) Modulus 200 GPa29 Msi · Shear Modulus 77 GPa11.2 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.29 · Hardness, Brinell 200 HB · Hardness, Rockwell B 92 HRB

Physical

Density and transition temperatures.

Same in both: Density 7.8 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,440°C2,624 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

425°C797 °F
370°C698 °F

Same in both: Thermal Conductivity 16 W/m·K9.2 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.5 µm/m·K6.4 µin/in·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.1 % IACS · Electrical Resistivity 8.3×10⁻⁷ Ω·m32.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
22%

Formability (cold)

60 / 100
8 / 100

Same in both: Weldability 50 / 100 · Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 68 MJ/kg29,235 BTU/lb · Embodied Carbon (primary production) 5.4 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale15-7 Mo

15-7 Mo Condition A vs 15-7 Mo-RH950 — frequently asked

Is 15-7 Mo-RH950 stronger than 15-7 Mo Condition A?

Yes. 15-7 Mo-RH950 has a typical yield strength of 1,520 MPa (220 ksi) against 415 MPa (60.2 ksi) for 15-7 Mo Condition A — about 3.7 times as much. Tensile strength is 1,620 MPa (235 ksi) vs 950 MPa (138 ksi).

Which condition does FabDigit quote by default, Condition A or RH950?

Condition A is the default 15-7 Mo condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 15-7 Mo Condition A or 15-7 Mo-RH950?

15-7 Mo Condition A. Its machinability rates fair (45/100) against poor (22/100) for 15-7 Mo-RH950.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 15-7 Mo Condition A and 15-7 Mo-RH950 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.