FabDigitFabDigit

Stainless Steel 1.4887-AW vs 1.4887-CD

Stainless Steel · 1.4887 temper comparison

1.4887-AW and 1.4887-CD are two conditions of the same stainless steel grade, 1.4887: AW (as-welded deposit) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4887-CD is the stronger of the two: yield strength 420 MPa (60.9 ksi) against 260 MPa (37.7 ksi) for 1.4887-AW, about 62% more; tensile strength follows at 680 MPa (98.6 ksi) vs 470 MPa (68.2 ksi). 1.4887-CD is the more ductile: elongation 20% versus 15% for 1.4887-AW, and 1.4887-CD is harder (215 HB vs 180 HB).

1.4887-CDChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1.4887-AW vs 1.4887-CD: properties

1.4887-AW1.4887-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
680 MPa98.6 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
420 MPa60.9 ksi

Elongation at Break

15%
20%

Reduction in Area

20%
30%

Shear Strength

330 MPa47.9 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

180 HB
215 HB

Hardness, Rockwell B

89 HRB
95 HRB

Hardness, Vickers

190 HV
225 HV

Same in both: Elastic (Young's) Modulus 190 GPa27.6 Msi · Shear Modulus 73 GPa10.6 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,340°C2,444 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

1,050°C1,922 °F
1,100°C2,012 °F

Same in both: Thermal Conductivity 13 W/m·K7.5 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.5 µm/m·K8.6 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.02×10⁻⁶ Ω·m40.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

48 / 100
55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
27 / 100

Machinability Rating (AISI 1212 = 100 %)

27%
32%

Formability (cold)

25 / 100
35 / 100

Same in both: Weldability 55 / 100 · Castability 75 / 100 · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 6 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4887

1.4887-AW vs 1.4887-CD — frequently asked

Is 1.4887-CD stronger than 1.4887-AW?

Yes. 1.4887-CD has a typical yield strength of 420 MPa (60.9 ksi) against 260 MPa (37.7 ksi) for 1.4887-AW — about 62% more. Tensile strength is 680 MPa (98.6 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, AW or CD?

SA is the default 1.4887 condition in the FabDigit quote flow (neither AW nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4887-AW or 1.4887-CD?

1.4887-CD, by a small margin. Both rate poor for machinability — 27/100 against 22/100 for 1.4887-AW.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4887-AW and 1.4887-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.