FabDigitFabDigit

Stainless Steel 1.4887-CD vs 1.4887-SA

Stainless Steel · 1.4887 temper comparison

1.4887-CD and 1.4887-SA are two conditions of the same stainless steel grade, 1.4887: CD (cold drawn) versus SA (solution Annealed). The chemistry is identical, so every difference below comes from the condition. 1.4887-CD is the stronger of the two: yield strength 420 MPa (60.9 ksi) against 250 MPa (36.3 ksi) for 1.4887-SA, about 68% more; tensile strength follows at 680 MPa (98.6 ksi) vs 560 MPa (81.2 ksi). In exchange, 1.4887-SA is the more ductile: elongation 35% versus 20% for 1.4887-CD, and 1.4887-CD is harder (215 HB vs 170 HB). On the shop floor, 1.4887-SA welds better (65 vs 55 out of 100).

1.4887-CDChoose it when strength drives the design.

1.4887-SAChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

1.4887-CD vs 1.4887-SA: properties

1.4887-CD1.4887-SA

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

680 MPa98.6 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
250 MPa36.3 ksi

Elongation at Break

20%
35%

Reduction in Area

30%
45%

Shear Strength

450 MPa65.3 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
210 MPa30.5 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

215 HB
170 HB

Hardness, Rockwell B

95 HRB
87 HRB

Hardness, Vickers

225 HV
180 HV

Same in both: Elastic (Young's) Modulus 190 GPa27.6 Msi · Shear Modulus 73 GPa10.6 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,340°C2,444 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 13 W/m·K7.5 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.5 µm/m·K8.6 µin/in·°F · Max Service Temperature (continuous) 1,100°C2,012 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.02×10⁻⁶ Ω·m40.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

27 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
30%

Weldability

55 / 100
65 / 100

Formability (cold)

35 / 100
55 / 100

Same in both: Castability 75 / 100 · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 6 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4887

1.4887-CD vs 1.4887-SA — frequently asked

Is 1.4887-CD stronger than 1.4887-SA?

Yes. 1.4887-CD has a typical yield strength of 420 MPa (60.9 ksi) against 250 MPa (36.3 ksi) for 1.4887-SA — about 68% more. Tensile strength is 680 MPa (98.6 ksi) vs 560 MPa (81.2 ksi).

Which condition does FabDigit quote by default, CD or SA?

SA is the default 1.4887 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, 1.4887-CD or 1.4887-SA?

1.4887-SA. Its weldability rates good (65/100) against good (55/100) for 1.4887-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4887-CD and 1.4887-SA side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.