FabDigitFabDigit

Stainless Steel 1.4887 CAST-S vs 1.4887-CD

Stainless Steel · 1.4887 temper comparison

1.4887 CAST-S and 1.4887-CD are two conditions of the same stainless steel grade, 1.4887: CAST-S (as-Cast, statically (sand/investment) cast) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 1.4887-CD is the stronger of the two: yield strength 420 MPa (60.9 ksi) against 230 MPa (33.4 ksi) for 1.4887 CAST-S, about 83% more; tensile strength follows at 680 MPa (98.6 ksi) vs 450 MPa (65.3 ksi). 1.4887-CD is the more ductile: elongation 20% versus 10% for 1.4887 CAST-S, and 1.4887-CD is harder (215 HB vs 180 HB). 1.4887-CD is stiffer (190 GPa vs 180 GPa). On the shop floor, 1.4887-CD welds better (good vs fair).

1.4887-CDChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

1.4887 CAST-S vs 1.4887-CD: properties

1.4887 CAST-S1.4887-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

180 GPa26.1 Msi
190 GPa27.6 Msi

Tensile Strength (Ultimate)

450 MPa65.3 ksi
680 MPa98.6 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
420 MPa60.9 ksi

Elongation at Break

10%
20%

Reduction in Area

13%
30%

Shear Strength

320 MPa46.4 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

180 HB
215 HB

Hardness, Rockwell B

89 HRB
95 HRB

Hardness, Vickers

190 HV
225 HV

Same in both: Shear Modulus 73 GPa10.6 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 7.9 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,340°C2,444 °F · Liquidus Temperature 1,400°C2,552 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

1,050°C1,922 °F
1,100°C2,012 °F

Same in both: Thermal Conductivity 13 W/m·K7.5 BTU/hr·ft·°F · Specific Heat Capacity 500 J/kg·K0.12 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.5 µm/m·K8.6 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.02×10⁻⁶ Ω·m40.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

53 / 100
55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
27 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
32%

Weldability

45 / 100
55 / 100

Formability (cold)

10 / 100
35 / 100

Same in both: Castability 75 / 100 · Brazeability / Solderability 45 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 6 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4887

1.4887 CAST-S vs 1.4887-CD — frequently asked

Is 1.4887-CD stronger than 1.4887 CAST-S?

Yes. 1.4887-CD has a typical yield strength of 420 MPa (60.9 ksi) against 230 MPa (33.4 ksi) for 1.4887 CAST-S — about 83% more. Tensile strength is 680 MPa (98.6 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, CAST-S or CD?

SA is the default 1.4887 condition in the FabDigit quote flow (neither CAST-S nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4887 CAST-S or 1.4887-CD?

1.4887-CD, by a small margin. Both rate poor for machinability — 27/100 against 18/100 for 1.4887 CAST-S; for welding the order is 1.4887-CD first (good, 55/100) then 1.4887 CAST-S (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4887 CAST-S and 1.4887-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.