FabDigitFabDigit

Stainless Steel 1.4470 vs CD3MCuN

Stainless Steel · grade comparison

Stainless Steel 1.4470 and CD3MCuN are both stainless steel grades. CD3MCuN is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 500 MPa (72.5 ksi) for 1.4470, about 10% more; tensile strength follows at 740 MPa (107 ksi) vs 700 MPa (102 ksi). CD3MCuN runs hotter in service (300°C vs 260°C continuous). On the shop floor, 1.4470 sits in a lower cost tier (premium, $$$) than CD3MCuN (high, $$$$).

1.4470Choose it when cost is the deciding factor.

CD3MCuNChoose it when strength drives the design, or when the part sees heat.

1.4470 vs CD3MCuN: properties

1.4470CD3MCuN

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

195 GPa28.3 Msi
200 GPa29 Msi

Shear Modulus

76 GPa11 Msi
77 GPa11.2 Msi

Tensile Strength (Ultimate)

700 MPa102 ksi
740 MPa107 ksi

Yield Strength (0.2% offset)

500 MPa72.5 ksi
550 MPa79.8 ksi

Elongation at Break

30%
32%

Compressive Strength

510 MPa74 ksi
560 MPa81.2 ksi

Shear Strength

430 MPa62.4 ksi
450 MPa65.3 ksi

Fracture Toughness (K_IC)

120 MPa·√m109 ksi·√in
100 MPa·√m91 ksi·√in

Charpy V-Notch Impact (RT)

100 J73.8 ft·lbf
80 J59 ft·lbf

Same in both: Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.3 · Reduction in Area 45% · Fatigue Strength (Endurance Limit) 300 MPa43.5 ksi · Hardness, Brinell 230 HB · Hardness, Rockwell B 98 HRB · Hardness, Rockwell C 21 HRC · Hardness, Vickers 245 HV

Physical

Density and transition temperatures.

Density

7.8 g/cm³0.28 lb/in³
7.75 g/cm³0.28 lb/in³

Melting Point (Solidus)

1,400°C2,552 °F
1,380°C2,516 °F

Liquidus Temperature

1,460°C2,660 °F
1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

15.5 W/m·K9 BTU/hr·ft·°F
16 W/m·K9.2 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

13 µm/m·K7.2 µin/in·°F
12.8 µm/m·K7.1 µin/in·°F

Max Service Temperature (continuous)

260°C500 °F
300°C572 °F

Same in both: Specific Heat Capacity 480 J/kg·K0.11 BTU/lb·°F · Latent Heat of Fusion 270 J/g116 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.2 % IACS · Electrical Resistivity 8×10⁻⁷ Ω·m31.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
22%

Weldability

70 / 100
62 / 100

Formability (cold)

20 / 100
25 / 100

Castability

68 / 100
65 / 100

Brazeability / Solderability

40 / 100
35 / 100

Polishability

65 / 100
70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

55 MJ/kg23,646 BTU/lb
47 MJ/kg20,206 BTU/lb

Embodied Carbon (primary production)

5 kg CO₂/kg
3.6 kg CO₂/kg

Typical Recycled Content

80%
70%

Same in both: Embodied Water 190 L/kg22.8 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

90 kN·m/kg
95 kN·m/kg

Specific Stiffness (E / density)

25 MN·m/kg
25.8 MN·m/kg

Modulus of Resilience

641 kJ/m³
756 kJ/m³

Thermal Diffusivity

4.1 mm²/s
4.3 mm²/s

Thermal Shock Resistance Index

4
5

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scaleCD3MCuN1.4470

Manufacturing and finishing

Capability1.4470CD3MCuN
Default condition——
Relative cost$$$ Premium$$$$ High
Min. machined wall——
Best machined surface——

Both take the same 7 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Hard Chrome Plating, Pickling, Plasma Spray, Silver Plating.

1.4470 vs CD3MCuN — frequently asked

Is CD3MCuN stronger than 1.4470?

Yes. CD3MCuN has a typical yield strength of 550 MPa (79.8 ksi) against 500 MPa (72.5 ksi) for 1.4470 — about 10% more. Tensile strength is 740 MPa (107 ksi) vs 700 MPa (102 ksi).

Which is cheaper, 1.4470 or CD3MCuN?

1.4470 is the lower-cost material: it sits in the premium tier ($$$) while CD3MCuN is high ($$$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which welds better, 1.4470 or CD3MCuN?

1.4470. Its weldability rates very good (70/100) against good (62/100) for CD3MCuN.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4470 and CD3MCuN side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.