FabDigitFabDigit

Stainless Steel 1.4112 +A vs 1.4112 QT-56

Stainless Steel · 1.4112 temper comparison

1.4112 +A and 1.4112 QT-56 are two conditions of the same stainless steel grade, 1.4112: +A (annealed) versus QT-56 (hardened + tempered ~200 °C). The chemistry is identical, so every difference below comes from the condition. 1.4112 QT-56 is the stronger of the two: yield strength 1,700 MPa (247 ksi) against 470 MPa (68.2 ksi) for 1.4112 +A, about 3.6 times as much; tensile strength follows at 1,900 MPa (276 ksi) vs 800 MPa (116 ksi). In exchange, 1.4112 +A is the more ductile: elongation 16% versus 2.5% for 1.4112 QT-56, and 1.4112 QT-56 is harder (56 HRC vs 24 HRC). 1.4112 +A runs hotter in service (400°C vs 200°C continuous). On the shop floor, 1.4112 +A machines more easily (fair vs not recommended).

1.4112 +AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1.4112 QT-56Choose it when strength drives the design.

1.4112 +A vs 1.4112 QT-56: properties

1.4112 +A1.4112 QT-56

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

800 MPa116 ksi
1,900 MPa276 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
1,700 MPa247 ksi

Elongation at Break

16%
2.5%

Compressive Strength

500 MPa72.5 ksi
2,200 MPa319 ksi

Shear Strength

500 MPa72.5 ksi
1,150 MPa167 ksi

Fatigue Strength (Endurance Limit)

360 MPa52.2 ksi
720 MPa104 ksi

Fracture Toughness (K_IC)

60 MPa·√m54.6 ksi·√in
20 MPa·√m18.2 ksi·√in

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
9 J6.6 ft·lbf

Hardness, Rockwell C

24 HRC
56 HRC

Hardness, Vickers

260 HV
620 HV

Same in both: Elastic (Young's) Modulus 215 GPa31.2 Msi · Shear Modulus 83 GPa12 Msi · Bulk Modulus 160 GPa23.2 Msi · Poisson's Ratio 0.28 · Reduction in Area 35% · Hardness, Brinell 250 HB

Physical

Density and transition temperatures.

Same in both: Density 7.7 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,465°C2,669 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

400°C752 °F
200°C392 °F

Same in both: Thermal Conductivity 15 W/m·K8.7 BTU/hr·ft·°F · Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 10.4 µm/m·K5.8 µin/in·°F · Latent Heat of Fusion 260 J/g112 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.7 % IACS · Electrical Resistivity 6.5×10⁻⁷ Ω·m25.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

38 / 100
47 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
5 / 100

Polishability

80 / 100
88 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 40% · Weldability 15 / 100 · Formability (cold) 20 / 100 · Castability 30 / 100 · Brazeability / Solderability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4.8 kg CO₂/kg · Embodied Water 180 L/kg21.6 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every stainless steel grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0001,5002,0007.27.47.67.888.2Density (g/cm³)Yield strength (MPa) — log scale1.4112

1.4112 +A vs 1.4112 QT-56 — frequently asked

Is 1.4112 QT-56 stronger than 1.4112 +A?

Yes. 1.4112 QT-56 has a typical yield strength of 1,700 MPa (247 ksi) against 470 MPa (68.2 ksi) for 1.4112 +A — about 3.6 times as much. Tensile strength is 1,900 MPa (276 ksi) vs 800 MPa (116 ksi).

Which condition does FabDigit quote by default, +A or QT-56?

+A is the default 1.4112 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1.4112 +A or 1.4112 QT-56?

1.4112 +A. Its machinability rates fair (35/100) against not recommended (5/100) for 1.4112 QT-56.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1.4112 +A and 1.4112 QT-56 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.