Precious Metal AgCu-Eutectic-AB vs AgCu-Eutectic-H02
Precious Metal · AgCu-Eutectic temper comparison
AgCu-Eutectic-AB and AgCu-Eutectic-H02 are two conditions of the same precious metal grade, AgCu-Eutectic: AB (as built (as printed)) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. AgCu-Eutectic-H02 is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 150 MPa (21.8 ksi) for AgCu-Eutectic-AB, about 120% more; tensile strength follows at 420 MPa (60.9 ksi) vs 275 MPa (39.9 ksi). In exchange, AgCu-Eutectic-AB is the more ductile: elongation 18% versus 10% for AgCu-Eutectic-H02, and AgCu-Eutectic-H02 is harder (105 HB vs 60 HB). AgCu-Eutectic-AB runs hotter in service (300°C vs 180°C continuous). On the shop floor, AgCu-Eutectic-H02 machines more easily (good vs fair).
AgCu-Eutectic-ABChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.
AgCu-Eutectic-H02Choose it when strength drives the design, or when the part is machined in volume.
AgCu-Eutectic-AB vs AgCu-Eutectic-H02: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all precious metal grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all precious metal grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
AgCu-Eutectic-ABAgCu-Eutectic-H02
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Shear Modulus 32 GPa4.6 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.36
Physical
Density and transition temperatures.
Same in both: Density 9.9 g/cm³0.36 lb/in³ · Melting Point (Solidus) 779°C1,434 °F · Liquidus Temperature 780°C1,436 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 275 J/kg·K0.07 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19 µm/m·K10.6 µin/in·°F · Latent Heat of Fusion 140 J/g60.2 BTU/lb · Min Service Temperature -200°C-328 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 85 / 100 · Brazeability / Solderability 98 / 100 · Polishability 88 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 1,130 MJ/kg485,813 BTU/lb · Embodied Carbon (primary production) 80 kg CO₂/kg · Embodied Water 90,000 L/kg10,784 gal/lb · Typical Recycled Content 45%
Strength versus weight
Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
AgCu-Eutectic-AB vs AgCu-Eutectic-H02 — frequently asked
Is AgCu-Eutectic-H02 stronger than AgCu-Eutectic-AB?
Yes. AgCu-Eutectic-H02 has a typical yield strength of 330 MPa (47.9 ksi) against 150 MPa (21.8 ksi) for AgCu-Eutectic-AB — about 120% more. Tensile strength is 420 MPa (60.9 ksi) vs 275 MPa (39.9 ksi).
Which condition does FabDigit quote by default, AB or H02?
O is the default AgCu-Eutectic condition in the FabDigit quote flow (neither AB nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, AgCu-Eutectic-AB or AgCu-Eutectic-H02?
AgCu-Eutectic-H02. Its machinability rates good (60/100) against fair (50/100) for AgCu-Eutectic-AB.
Ready to make it?
Upload a CAD file and FabDigit prices the part in AgCu-Eutectic-AB and AgCu-Eutectic-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.
