FabDigitFabDigit

Precious Metal AgCu-Eutectic-H02 vs AgCu-Eutectic-H04

Precious Metal · AgCu-Eutectic temper comparison

AgCu-Eutectic-H02 and AgCu-Eutectic-H04 are two conditions of the same precious metal grade, AgCu-Eutectic: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. AgCu-Eutectic-H04 is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 330 MPa (47.9 ksi) for AgCu-Eutectic-H02, about 45% more; tensile strength follows at 550 MPa (79.8 ksi) vs 420 MPa (60.9 ksi). In exchange, AgCu-Eutectic-H02 is the more ductile: elongation 10% versus 3% for AgCu-Eutectic-H04, and AgCu-Eutectic-H04 is harder (138 HB vs 105 HB). AgCu-Eutectic-H04 runs hotter in service (300°C vs 180°C continuous).

AgCu-Eutectic-H02Choose it when the part is bent, formed or impact-loaded.

AgCu-Eutectic-H04Choose it when strength drives the design, or when the part sees heat.

AgCu-Eutectic-H02 vs AgCu-Eutectic-H04: properties

AgCu-Eutectic-H02AgCu-Eutectic-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
480 MPa69.6 ksi

Elongation at Break

10%
3%

Reduction in Area

25%
45%

Shear Strength

255 MPa37 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
170 MPa24.7 ksi

Hardness, Brinell

105 HB
138 HB

Hardness, Rockwell B

62 HRB
76 HRB

Hardness, Vickers

110 HV
145 HV

Same in both: Elastic (Young's) Modulus 85 GPa12.3 Msi · Shear Modulus 32 GPa4.6 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.36

Physical

Density and transition temperatures.

Same in both: Density 9.9 g/cm³0.36 lb/in³ · Melting Point (Solidus) 779°C1,434 °F · Liquidus Temperature 780°C1,436 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

348 W/m·K201 BTU/hr·ft·°F
355 W/m·K205 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
300°C572 °F

Same in both: Specific Heat Capacity 275 J/kg·K0.07 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19 µm/m·K10.6 µin/in·°F · Latent Heat of Fusion 140 J/g60.2 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

84 % IACS
83 % IACS

Electrical Resistivity

2.05×10⁻⁸ Ω·m0.807 µΩ·in
2×10⁻⁸ Ω·m0.787 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.05 V · Corrosion Resistance 75 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
50%

Weldability

38 / 100
40 / 100

Formability (cold)

60 / 100
35 / 100

Same in both: Castability 85 / 100 · Brazeability / Solderability 98 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 1,130 MJ/kg485,813 BTU/lb · Embodied Carbon (primary production) 80 kg CO₂/kg · Embodied Water 90,000 L/kg10,784 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every precious metal grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

50100200500101520Density (g/cm³)Yield strength (MPa) — log scaleAgCu-Eutectic

AgCu-Eutectic-H02 vs AgCu-Eutectic-H04 — frequently asked

Is AgCu-Eutectic-H04 stronger than AgCu-Eutectic-H02?

Yes. AgCu-Eutectic-H04 has a typical yield strength of 480 MPa (69.6 ksi) against 330 MPa (47.9 ksi) for AgCu-Eutectic-H02 — about 45% more. Tensile strength is 550 MPa (79.8 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, H02 or H04?

O is the default AgCu-Eutectic condition in the FabDigit quote flow (neither H02 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, AgCu-Eutectic-H02 or AgCu-Eutectic-H04?

AgCu-Eutectic-H04, by a small margin. Both rate good for machinability — 65/100 against 60/100 for AgCu-Eutectic-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in AgCu-Eutectic-H02 and AgCu-Eutectic-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.