FabDigitFabDigit

Nickel Alloy N06110-AW vs N06110-CD

Nickel Alloy · N06110 temper comparison

N06110-AW and N06110-CD are two conditions of the same nickel alloy grade, N06110: AW (as-welded deposit) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. N06110-CD is the stronger of the two: yield strength 830 MPa (120 ksi) against 420 MPa (60.9 ksi) for N06110-AW, about 98% more; tensile strength follows at 1,000 MPa (145 ksi) vs 760 MPa (110 ksi). In exchange, N06110-AW is the more ductile: elongation 35% versus 22% for N06110-CD, and N06110-CD is harder (300 HB vs 195 HB). N06110-AW runs hotter in service (650°C vs 540°C continuous). On the shop floor, N06110-AW welds better (very good vs good).

N06110-AWChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

N06110-CDChoose it when strength drives the design.

N06110-AW vs N06110-CD: properties

N06110-AWN06110-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

205 GPa29.7 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

760 MPa110 ksi
1,000 MPa145 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
830 MPa120 ksi

Elongation at Break

35%
22%

Reduction in Area

40%
45%

Shear Strength

470 MPa68.2 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
400 MPa58 ksi

Charpy V-Notch Impact (RT)

110 J81.1 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

195 HB
300 HB

Hardness, Rockwell B

91 HRB
93 HRB

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 175 GPa25.4 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.4 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,330°C2,426 °F · Liquidus Temperature 1,380°C2,516 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

650°C1,202 °F
540°C1,004 °F

Same in both: Thermal Conductivity 9 W/m·K5.2 BTU/hr·ft·°F · Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 12.3 µm/m·K6.8 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.4 % IACS · Electrical Resistivity 1.25×10⁻⁶ Ω·m49.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

85 / 100
88 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

70 / 100
60 / 100

Formability (cold)

40 / 100
30 / 100

Same in both: Machinability 14 / 100 · Machinability Rating (AISI 1212 = 100 %) 10% · Castability 35 / 100 · Brazeability / Solderability 55 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 150 MJ/kg64,488 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleN06110

N06110-AW vs N06110-CD — frequently asked

Is N06110-CD stronger than N06110-AW?

Yes. N06110-CD has a typical yield strength of 830 MPa (120 ksi) against 420 MPa (60.9 ksi) for N06110-AW — about 98% more. Tensile strength is 1,000 MPa (145 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, AW or CD?

SA is the default N06110 condition in the FabDigit quote flow (neither AW nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, N06110-AW or N06110-CD?

N06110-AW. Its weldability rates very good (70/100) against good (60/100) for N06110-CD.

Ready to make it?

Upload a CAD file and FabDigit prices the part in N06110-AW and N06110-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.