FabDigitFabDigit

Nickel Alloy Monel K500 Cold Drawn vs Monel K500 Spring

Nickel Alloy · Monel K500 temper comparison

Monel K500 Cold Drawn and Monel K500 Spring are two conditions of the same nickel alloy grade, Monel K500: Cold Drawn versus Spring (spring hard). The chemistry is identical, so every difference below comes from the condition. Monel K500 Spring is the stronger of the two: yield strength 1,100 MPa (160 ksi) against 585 MPa (84.8 ksi) for Monel K500 Cold Drawn, about 88% more; tensile strength follows at 1,350 MPa (196 ksi) vs 800 MPa (116 ksi). In exchange, Monel K500 Cold Drawn is the more ductile: elongation 22% versus 12% for Monel K500 Spring, and Monel K500 Spring is harder (360 HB vs 215 HB). Monel K500 Cold Drawn runs hotter in service (480°C vs 300°C continuous). On the shop floor, Monel K500 Cold Drawn machines more easily (30 vs 18 out of 100).

Monel K500 Cold DrawnChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Monel K500 SpringChoose it when strength drives the design.

Monel K500 Cold Drawn vs Monel K500 Spring: properties

Monel K500 Cold DrawnMonel K500 Spring

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

177 GPa25.7 Msi
182 GPa26.4 Msi

Bulk Modulus

155 GPa22.5 Msi
167 GPa24.2 Msi

Tensile Strength (Ultimate)

800 MPa116 ksi
1,350 MPa196 ksi

Yield Strength (0.2% offset)

585 MPa84.8 ksi
1,100 MPa160 ksi

Elongation at Break

22%
12%

Reduction in Area

42%
30%

Shear Strength

505 MPa73.2 ksi
800 MPa116 ksi

Fatigue Strength (Endurance Limit)

285 MPa41.3 ksi
400 MPa58 ksi

Fracture Toughness (K_IC)

110 MPa·√m100 ksi·√in
75 MPa·√m68.3 ksi·√in

Charpy V-Notch Impact (RT)

135 J99.6 ft·lbf
24 J17.7 ft·lbf

Hardness, Brinell

215 HB
360 HB

Hardness, Rockwell B

96 HRB
75 HRB

Hardness, Rockwell C

20 HRC
38 HRC

Same in both: Shear Modulus 66 GPa9.6 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.44 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,315°C2,399 °F · Liquidus Temperature 1,350°C2,462 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

17.4 W/m·K10.1 BTU/hr·ft·°F
17.5 W/m·K10.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

480°C896 °F
300°C572 °F

Min Service Temperature

-250°C-418 °F
-200°C-328 °F

Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.7 µm/m·K7.6 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb

Electrical

Conductivity and insulation.

Electrical Resistivity

6.15×10⁻⁷ Ω·m24.2 µΩ·in
6.1×10⁻⁷ Ω·m24 µΩ·in

Same in both: Electrical Conductivity 2.8 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.15 V
-0.1 V

Corrosion Resistance

82 / 100
76 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
12%

Weldability

40 / 100
35 / 100

Formability (cold)

40 / 100
8 / 100

Brazeability / Solderability

60 / 100
45 / 100

Polishability

75 / 100
70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

140 MJ/kg60,189 BTU/lb
150 MJ/kg64,488 BTU/lb

Embodied Carbon (primary production)

10.5 kg CO₂/kg
12 kg CO₂/kg

Same in both: Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleMonel K500

Monel K500 Cold Drawn vs Monel K500 Spring — frequently asked

Is Monel K500 Spring stronger than Monel K500 Cold Drawn?

Yes. Monel K500 Spring has a typical yield strength of 1,100 MPa (160 ksi) against 585 MPa (84.8 ksi) for Monel K500 Cold Drawn — about 88% more. Tensile strength is 1,350 MPa (196 ksi) vs 800 MPa (116 ksi).

Which condition does FabDigit quote by default, Cold Drawn or Spring?

O is the default Monel K500 condition in the FabDigit quote flow (neither Cold Drawn nor Spring). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Monel K500 Cold Drawn or Monel K500 Spring?

Monel K500 Cold Drawn, by a small margin. Both rate poor for machinability — 30/100 against 18/100 for Monel K500 Spring; for welding the order is Monel K500 Cold Drawn first (fair, 40/100) then Monel K500 Spring (fair, 35/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in Monel K500 Cold Drawn and Monel K500 Spring side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.