Nickel Alloy Monel K500 CD+AT vs Monel K500 Cold Drawn
Nickel Alloy · Monel K500 temper comparison
Monel K500 CD+AT and Monel K500 Cold Drawn are two conditions of the same nickel alloy grade, Monel K500: CD+AT (cold drawn and age hardened) versus Cold Drawn. The chemistry is identical, so every difference below comes from the condition. Monel K500 CD+AT is the stronger of the two: yield strength 965 MPa (140 ksi) against 585 MPa (84.8 ksi) for Monel K500 Cold Drawn, about 65% more; tensile strength follows at 1,240 MPa (180 ksi) vs 800 MPa (116 ksi). In exchange, Monel K500 Cold Drawn is the more ductile: elongation 22% versus 17% for Monel K500 CD+AT, and Monel K500 CD+AT is harder (340 HB vs 215 HB). On the shop floor, Monel K500 CD+AT welds better (good vs fair).
Monel K500 CD+ATChoose it when strength drives the design, or when it will be welded.
Monel K500 Cold DrawnChoose it when the part is bent, formed or impact-loaded.
Monel K500 CD+AT vs Monel K500 Cold Drawn: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all nickel alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all nickel alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Monel K500 CD+ATMonel K500 Cold Drawn
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Bulk Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Rockwell C
Same in both: Shear Modulus 66 GPa9.6 Msi · Poisson's Ratio 0.32 · Fracture Toughness (K_IC) 110 MPa·√m100 ksi·√in
Physical
Density and transition temperatures.
Same in both: Density 8.44 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,315°C2,399 °F · Liquidus Temperature 1,350°C2,462 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Min Service Temperature
Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.7 µm/m·K7.6 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Max Service Temperature (continuous) 480°C896 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 2.8 % IACS · Electrical Resistivity 6.15×10⁻⁷ Ω·m24.2 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Galvanic Potential (seawater, vs SCE)
Corrosion Resistance
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Brazeability / Solderability
Polishability
Sustainability
Primary-production footprint per kilogram.
Embodied Energy (primary production)
Embodied Carbon (primary production)
Same in both: Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
Monel K500 CD+AT vs Monel K500 Cold Drawn — frequently asked
Is Monel K500 CD+AT stronger than Monel K500 Cold Drawn?
Yes. Monel K500 CD+AT has a typical yield strength of 965 MPa (140 ksi) against 585 MPa (84.8 ksi) for Monel K500 Cold Drawn — about 65% more. Tensile strength is 1,240 MPa (180 ksi) vs 800 MPa (116 ksi).
Which condition does FabDigit quote by default, CD+AT or Cold Drawn?
O is the default Monel K500 condition in the FabDigit quote flow (neither CD+AT nor Cold Drawn). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, Monel K500 CD+AT or Monel K500 Cold Drawn?
Monel K500 Cold Drawn, by a small margin. Both rate poor for machinability — 30/100 against 22/100 for Monel K500 CD+AT; for welding the order is Monel K500 CD+AT first (good, 65/100) then Monel K500 Cold Drawn (fair, 40/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in Monel K500 CD+AT and Monel K500 Cold Drawn side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.