Kovar 1/2H and Kovar-CD are two conditions of the same nickel alloy grade, Kovar: 1/2H (half hard) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. Kovar 1/2H is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 540 MPa (78.3 ksi) for Kovar-CD, about 15% more; tensile strength follows at 720 MPa (104 ksi) vs 660 MPa (95.7 ksi). In exchange, Kovar-CD is the more ductile: elongation 14% versus 8% for Kovar 1/2H, and Kovar 1/2H is harder (238 HB vs 209 HB). Kovar-CD runs hotter in service (300°C vs 250°C continuous).

Kovar 1/2HChoose it when strength drives the design.

Kovar-CDChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Kovar 1/2H vs Kovar-CD: properties

Kovar 1/2HKovar-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

720 MPa104 ksi
660 MPa95.7 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
540 MPa78.3 ksi

Elongation at Break

8%
14%

Reduction in Area

40%
50%

Shear Strength

480 MPa69.6 ksi
440 MPa63.8 ksi

Fatigue Strength (Endurance Limit)

330 MPa47.9 ksi
310 MPa45 ksi

Hardness, Brinell

238 HB
209 HB

Hardness, Rockwell B

100 HRB
95 HRB

Hardness, Vickers

250 HV
220 HV

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 52 GPa7.5 Msi · Bulk Modulus 126 GPa18.3 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.36 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,450°C2,642 °F · Liquidus Temperature 1,455°C2,651 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
300°C572 °F

Same in both: Thermal Conductivity 17 W/m·K9.8 BTU/hr·ft·°F · Specific Heat Capacity 439 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 5.5 µm/m·K3.1 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 3.4 % IACS · Electrical Resistivity 5×10⁻⁷ Ω·m19.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.45 V · Corrosion Resistance 28 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

72 / 100
75 / 100

Formability (cold)

40 / 100
45 / 100

Same in both: Machinability 38 / 100 · Machinability Rating (AISI 1212 = 100 %) 38% · Brazeability / Solderability 90 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 100 MJ/kg42,992 BTU/lb · Embodied Carbon (primary production) 8 kg CO₂/kg · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scaleKovar

Kovar 1/2H vs Kovar-CD — frequently asked

Is Kovar 1/2H stronger than Kovar-CD?

Yes. Kovar 1/2H has a typical yield strength of 620 MPa (89.9 ksi) against 540 MPa (78.3 ksi) for Kovar-CD — about 15% more. Tensile strength is 720 MPa (104 ksi) vs 660 MPa (95.7 ksi).

Which condition does FabDigit quote by default, 1/2H or CD?

O is the default Kovar condition in the FabDigit quote flow (neither 1/2H nor CD). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Kovar 1/2H over Kovar-CD?

Pick Kovar 1/2H when strength drives the design. Pick Kovar-CD when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Kovar 1/2H and Kovar-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.