Haynes 230-AC and Haynes 230-AW are two conditions of the same nickel alloy grade, Haynes 230: AC (spheroidize annealed) versus AW (as-welded deposit). The chemistry is identical, so every difference below comes from the condition. Haynes 230-AW is the stronger of the two: yield strength 460 MPa (66.7 ksi) against 345 MPa (50 ksi) for Haynes 230-AC, about 33% more; tensile strength follows at 810 MPa (117 ksi) vs 620 MPa (89.9 ksi). Haynes 230-AW is the more ductile: elongation 30% versus 12% for Haynes 230-AC, and Haynes 230-AW is harder (225 HV vs 205 HV). On the shop floor, Haynes 230-AW welds better (very good vs good).
Haynes 230-AWChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.
Haynes 230-AC vs Haynes 230-AW: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all nickel alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all nickel alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 211 GPa30.6 Msi · Shear Modulus 81 GPa11.7 Msi · Bulk Modulus 185 GPa26.8 Msi · Poisson's Ratio 0.31
Physical
Density and transition temperatures.
Same in both: Density 8.97 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,301°C2,374 °F · Liquidus Temperature 1,371°C2,500 °F
Thermal
How each material carries heat and how hot it can run.
Max Service Temperature (continuous)
Same in both: Thermal Conductivity 8.9 W/m·K5.1 BTU/hr·ft·°F · Specific Heat Capacity 397 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 11.8 µm/m·K6.6 µin/in·°F · Latent Heat of Fusion 285 J/g123 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 1.4 % IACS · Electrical Resistivity 1.25×10⁻⁶ Ω·m49.2 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 45 / 100 · Brazeability / Solderability 65 / 100 · Polishability 70 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 230 MJ/kg98,882 BTU/lb · Embodied Carbon (primary production) 15 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 35%
Strength versus weight
Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
Haynes 230-AC vs Haynes 230-AW — frequently asked
Is Haynes 230-AW stronger than Haynes 230-AC?
Yes. Haynes 230-AW has a typical yield strength of 460 MPa (66.7 ksi) against 345 MPa (50 ksi) for Haynes 230-AC — about 33% more. Tensile strength is 810 MPa (117 ksi) vs 620 MPa (89.9 ksi).
Which condition does FabDigit quote by default, AC or AW?
SA is the default Haynes 230 condition in the FabDigit quote flow (neither AC nor AW). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which welds better, Haynes 230-AC or Haynes 230-AW?
Haynes 230-AW. Its weldability rates very good (75/100) against good (65/100) for Haynes 230-AC.
Ready to make it?
Upload a CAD file and FabDigit prices the part in Haynes 230-AC and Haynes 230-AW side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.