FabDigitFabDigit

Nickel Alloy 800-ANN vs 800-CD

Nickel Alloy · 800 temper comparison

800-ANN and 800-CD are two conditions of the same nickel alloy grade, 800: ANN (annealed) versus CD (cold drawn). The chemistry is identical, so every difference below comes from the condition. 800-CD is the stronger of the two: yield strength 500 MPa (72.5 ksi) against 250 MPa (36.3 ksi) for 800-ANN, about 100% more; tensile strength follows at 720 MPa (104 ksi) vs 600 MPa (87 ksi). In exchange, 800-ANN is the more ductile: elongation 45% versus 25% for 800-CD, and 800-CD is harder (210 HB vs 138 HB). 800-ANN runs hotter in service (815°C vs 550°C continuous).

800-ANNChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

800-CDChoose it when strength drives the design.

800-ANN vs 800-CD: properties

800-ANN800-CD

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

600 MPa87 ksi
720 MPa104 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
500 MPa72.5 ksi

Elongation at Break

45%
25%

Reduction in Area

60%
45%

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
310 MPa45 ksi

Charpy V-Notch Impact (RT)

160 J118 ft·lbf
90 J66.4 ft·lbf

Hardness, Brinell

138 HB
210 HB

Hardness, Rockwell B

80 HRB
95 HRB

Same in both: Elastic (Young's) Modulus 196.5 GPa28.5 Msi · Shear Modulus 76.5 GPa11.1 Msi · Bulk Modulus 203 GPa29.4 Msi · Poisson's Ratio 0.34 · Compressive Strength 250 MPa36.3 ksi · Shear Strength 400 MPa58 ksi · Hardness, Vickers 145 HV

Physical

Density and transition temperatures.

Same in both: Density 7.94 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,357°C2,475 °F · Liquidus Temperature 1,385°C2,525 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

815°C1,499 °F
550°C1,022 °F

Same in both: Thermal Conductivity 11.5 W/m·K6.6 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 14.4 µm/m·K8 µin/in·°F · Latent Heat of Fusion 290 J/g125 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 9.89×10⁻⁷ Ω·m38.9 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.15 V · Corrosion Resistance 75 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Formability (cold)

78 / 100
45 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 28% · Weldability 85 / 100 · Brazeability / Solderability 65 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every nickel alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

2005001,0006.577.588.59Density (g/cm³)Yield strength (MPa) — log scale800

800-ANN vs 800-CD — frequently asked

Is 800-CD stronger than 800-ANN?

Yes. 800-CD has a typical yield strength of 500 MPa (72.5 ksi) against 250 MPa (36.3 ksi) for 800-ANN — about 100% more. Tensile strength is 720 MPa (104 ksi) vs 600 MPa (87 ksi).

Which condition does FabDigit quote by default, ANN or CD?

ANN is the default 800 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 800-ANN or 800-CD?

800-CD. Its machinability rates fair (35/100) against poor (30/100) for 800-ANN.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 800-ANN and 800-CD side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.