FabDigitFabDigit

Copper Alloy CuAg0.07-H01 vs CuAg0.07-O60

Copper Alloy · CuAg0.07 temper comparison

CuAg0.07-H01 and CuAg0.07-O60 are two conditions of the same copper alloy grade, CuAg0.07: H01 (quarter hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. CuAg0.07-H01 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 70 MPa (10.2 ksi) for CuAg0.07-O60, about 3.1 times as much; tensile strength follows at 275 MPa (39.9 ksi) vs 220 MPa (31.9 ksi). In exchange, CuAg0.07-O60 is the more ductile: elongation 48% versus 25% for CuAg0.07-H01, and CuAg0.07-H01 is harder (70 HB vs 42 HB). CuAg0.07-H01 runs hotter in service (300°C vs 250°C continuous).

CuAg0.07-H01Choose it when strength drives the design, or when the part sees heat.

CuAg0.07-O60Choose it when the part is bent, formed or impact-loaded.

CuAg0.07-H01 vs CuAg0.07-O60: properties

CuAg0.07-H01CuAg0.07-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

275 MPa39.9 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
70 MPa10.2 ksi

Elongation at Break

25%
48%

Reduction in Area

70%
55%

Shear Strength

170 MPa24.7 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
70 MPa10.2 ksi

Charpy V-Notch Impact (RT)

75 J55.3 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

70 HB
42 HB

Hardness, Rockwell B

32 HRB
45 HRB

Hardness, Vickers

75 HV
45 HV

Same in both: Elastic (Young's) Modulus 120 GPa17.4 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.91 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

392 W/m·K226 BTU/hr·ft·°F
391 W/m·K226 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
250°C482 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

99 % IACS
101 % IACS

Electrical Resistivity

1.74×10⁻⁸ Ω·m0.685 µΩ·in
1.71×10⁻⁸ Ω·m0.673 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
18%

Formability (cold)

70 / 100
95 / 100

Same in both: Weldability 45 / 100 · Castability 55 / 100 · Brazeability / Solderability 90 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCuAg0.07

CuAg0.07-H01 vs CuAg0.07-O60 — frequently asked

Is CuAg0.07-H01 stronger than CuAg0.07-O60?

Yes. CuAg0.07-H01 has a typical yield strength of 215 MPa (31.2 ksi) against 70 MPa (10.2 ksi) for CuAg0.07-O60 — about 3.1 times as much. Tensile strength is 275 MPa (39.9 ksi) vs 220 MPa (31.9 ksi).

Which condition does FabDigit quote by default, H01 or O60?

H04 is the default CuAg0.07 condition in the FabDigit quote flow (neither H01 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CuAg0.07-H01 over CuAg0.07-O60?

Pick CuAg0.07-H01 when strength drives the design, or when the part sees heat. Pick CuAg0.07-O60 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CuAg0.07-H01 and CuAg0.07-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.