FabDigitFabDigit

Copper Alloy CC492K-GM vs CC492K-GS

Copper Alloy · CC492K temper comparison

CC492K-GM and CC492K-GS are two conditions of the same copper alloy grade, CC492K: GM (permanent (chill) mould cast) versus GS (sand cast). The chemistry is identical, so every difference below comes from the condition. CC492K-GM is the stronger of the two: yield strength 135 MPa (19.6 ksi) against 125 MPa (18.1 ksi) for CC492K-GS, about 8% more; tensile strength follows at 275 MPa (39.9 ksi) vs 245 MPa (35.5 ksi). In exchange, CC492K-GS is the more ductile: elongation 18% versus 14% for CC492K-GM, and CC492K-GM is harder (75 HB vs 68 HB).

CC492K-GMChoose it when strength drives the design.

CC492K-GSChoose it when the part is bent, formed or impact-loaded.

CC492K-GM vs CC492K-GS: properties

CC492K-GMCC492K-GS

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

97 GPa14.1 Msi
95 GPa13.8 Msi

Tensile Strength (Ultimate)

275 MPa39.9 ksi
245 MPa35.5 ksi

Yield Strength (0.2% offset)

135 MPa19.6 ksi
125 MPa18.1 ksi

Elongation at Break

14%
18%

Reduction in Area

17%
20%

Compressive Strength

305 MPa44.2 ksi
275 MPa39.9 ksi

Shear Strength

185 MPa26.8 ksi
175 MPa25.4 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
85 MPa12.3 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

75 HB
68 HB

Hardness, Rockwell B

40 HRB
32 HRB

Hardness, Vickers

79 HV
72 HV

Same in both: Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 850°C1,562 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 68 W/m·K39.3 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 230°C446 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 14 % IACS · Electrical Resistivity 1.23×10⁻⁷ Ω·m4.84 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

67 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 78 / 100 · Machinability Rating (AISI 1212 = 100 %) 90% · Weldability 30 / 100 · Formability (cold) 15 / 100 · Castability 88 / 100 · Brazeability / Solderability 82 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC492K

CC492K-GM vs CC492K-GS — frequently asked

Is CC492K-GM stronger than CC492K-GS?

Yes. CC492K-GM has a typical yield strength of 135 MPa (19.6 ksi) against 125 MPa (18.1 ksi) for CC492K-GS — about 8% more. Tensile strength is 275 MPa (39.9 ksi) vs 245 MPa (35.5 ksi).

Which condition does FabDigit quote by default, GM or GS?

GC is the default CC492K condition in the FabDigit quote flow (neither GM nor GS). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose CC492K-GM over CC492K-GS?

Pick CC492K-GM when strength drives the design. Pick CC492K-GS when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in CC492K-GM and CC492K-GS side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.