Copper Alloy CC490K and CC760S are both copper alloy grades. CC490K is the stronger of the two: yield strength 100 MPa (14.5 ksi) against 90 MPa (13.1 ksi) for CC760S, about 11% more. In exchange, CC760S is the more ductile: elongation 30% versus 20% for CC490K, and CC490K is harder (65 HB vs 55 HB). CC760S is stiffer (100 GPa vs 90 GPa) and CC760S conducts heat better (150 W/m·K vs 78 W/m·K). On the shop floor, CC490K machines more easily (very good vs fair) and CC760S welds better (fair vs poor).

CC490KChoose it when strength drives the design, or when the part is machined in volume.

CC760SChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

CC490K vs CC760S: properties

CC490KCC760S

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

90 GPa13.1 Msi
100 GPa14.5 Msi

Shear Modulus

36 GPa5.2 Msi
40 GPa5.8 Msi

Bulk Modulus

105 GPa15.2 Msi
112 GPa16.2 Msi

Tensile Strength (Ultimate)

215 MPa31.2 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

100 MPa14.5 ksi
90 MPa13.1 ksi

Elongation at Break

20%
30%

Reduction in Area

20%
35%

Shear Strength

160 MPa23.2 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
70 MPa10.2 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

65 HB
55 HB

Hardness, Rockwell B

25 HRB
15 HRB

Hardness, Vickers

68 HV
58 HV

Same in both: Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Density

8.7 g/cm³0.31 lb/in³
8.75 g/cm³0.32 lb/in³

Melting Point (Solidus)

900°C1,652 °F
1,000°C1,832 °F

Liquidus Temperature

1,000°C1,832 °F
1,025°C1,877 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

78 W/m·K45.1 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

18.5 µm/m·K10.3 µin/in·°F
18.7 µm/m·K10.4 µin/in·°F

Latent Heat of Fusion

205 J/g88.1 BTU/lb
200 J/g86 BTU/lb

Min Service Temperature

-100°C-148 °F
-200°C-328 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Max Service Temperature (continuous) 200°C392 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

15 % IACS
32 % IACS

Electrical Resistivity

1.15×10⁻⁷ Ω·m4.53 µΩ·in
5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.25 V
-0.26 V

Corrosion Resistance

70 / 100
68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

80 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

80%
30%

Weldability

25 / 100
45 / 100

Formability (cold)

10 / 100
50 / 100

Castability

85 / 100
70 / 100

Brazeability / Solderability

75 / 100
92 / 100

Polishability

60 / 100
80 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

55 MJ/kg23,646 BTU/lb
58 MJ/kg24,936 BTU/lb

Embodied Carbon (primary production)

3.6 kg CO₂/kg
4 kg CO₂/kg

Embodied Water

260 L/kg31.2 gal/lb
300 L/kg35.9 gal/lb

Typical Recycled Content

85%
50%

Common Calculations

Ratios derived from the values above.

Specific Stiffness (E / density)

10.3 MN·m/kg
11.4 MN·m/kg

Modulus of Resilience

56 kJ/m³
41 kJ/m³

Thermal Diffusivity

23.8 mm²/s
45.5 mm²/s

Thermal Shock Resistance Index

10
18

Same in both: Specific Strength (UTS / density) 25 kN·m/kg

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleCC490KCC760S

Manufacturing and finishing

CapabilityCC490KCC760S
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

Both take the same 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

CC490K vs CC760S — frequently asked

Is CC490K stronger than CC760S?

Yes. CC490K has a typical yield strength of 100 MPa (14.5 ksi) against 90 MPa (13.1 ksi) for CC760S — about 11% more. Tensile strength is 215 MPa (31.2 ksi) vs 220 MPa (31.9 ksi).

Which is cheaper, CC490K or CC760S?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, CC490K or CC760S?

CC490K. Its machinability rates very good (80/100) against fair (35/100) for CC760S; for welding the order is CC760S first (fair, 45/100) then CC490K (poor, 25/100).