Copper Alloy C94800-M01 vs C94800-TF00
Copper Alloy · C94800 temper comparison
C94800-M01 and C94800-TF00 are two conditions of the same copper alloy grade, C94800: M01 (as sand cast) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C94800-TF00 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 155 MPa (22.5 ksi) for C94800-M01, about 77% more; tensile strength follows at 415 MPa (60.2 ksi) vs 310 MPa (45 ksi). In exchange, C94800-M01 is the more ductile: elongation 35% versus 10% for C94800-TF00, and C94800-TF00 is harder (140 HB vs 80 HB). C94800-M01 runs hotter in service (230°C vs 200°C continuous) and C94800-TF00 conducts heat better (52 W/m·K vs 46 W/m·K). On the shop floor, C94800-M01 machines more easily (very good vs good).
C94800-M01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.
C94800-TF00Choose it when strength drives the design.
C94800-M01 vs C94800-TF00: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34
Physical
Density and transition temperatures.
Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 1,040°C1,904 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 65 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 80 / 100 · Brazeability / Solderability 75 / 100 · Polishability 60 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 55%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C94800-M01 vs C94800-TF00 — frequently asked
Is C94800-TF00 stronger than C94800-M01?
Yes. C94800-TF00 has a typical yield strength of 275 MPa (39.9 ksi) against 155 MPa (22.5 ksi) for C94800-M01 — about 77% more. Tensile strength is 415 MPa (60.2 ksi) vs 310 MPa (45 ksi).
Which condition does FabDigit quote by default, M01 or TF00?
M01 is the default C94800 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, C94800-M01 or C94800-TF00?
C94800-M01. Its machinability rates very good (80/100) against good (60/100) for C94800-TF00; for welding the order is C94800-M01 first (poor, 30/100) then C94800-TF00 (poor, 25/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in C94800-M01 and C94800-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.