FabDigitFabDigit

Copper Alloy C94800-M02 vs C94800-TF00

Copper Alloy · C94800 temper comparison

C94800-M02 and C94800-TF00 are two conditions of the same copper alloy grade, C94800: M02 (as centrifugally cast) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C94800-TF00 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 170 MPa (24.7 ksi) for C94800-M02, about 62% more; tensile strength follows at 415 MPa (60.2 ksi) vs 330 MPa (47.9 ksi). In exchange, C94800-M02 is the more ductile: elongation 30% versus 10% for C94800-TF00, and C94800-TF00 is harder (140 HB vs 85 HB). C94800-M02 runs hotter in service (230°C vs 200°C continuous) and C94800-TF00 conducts heat better (52 W/m·K vs 46 W/m·K). On the shop floor, C94800-M02 machines more easily (very good vs good).

C94800-M02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C94800-TF00Choose it when strength drives the design.

C94800-M02 vs C94800-TF00: properties

C94800-M02C94800-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

110 GPa16 Msi
115 GPa16.7 Msi

Tensile Strength (Ultimate)

330 MPa47.9 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
275 MPa39.9 ksi

Elongation at Break

30%
10%

Reduction in Area

25%
10%

Compressive Strength

500 MPa72.5 ksi
620 MPa89.9 ksi

Shear Strength

210 MPa30.5 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

120 MPa17.4 ksi
145 MPa21 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

85 HB
140 HB

Hardness, Rockwell B

45 HRB
76 HRB

Hardness, Vickers

89 HV
147 HV

Same in both: Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 1,040°C1,904 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

46 W/m·K26.6 BTU/hr·ft·°F
52 W/m·K30 BTU/hr·ft·°F

Max Service Temperature (continuous)

230°C446 °F
200°C392 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
13 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.33×10⁻⁷ Ω·m5.24 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

80 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

80%
60%

Weldability

30 / 100
25 / 100

Formability (cold)

10 / 100
5 / 100

Same in both: Castability 80 / 100 · Brazeability / Solderability 75 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC94800

C94800-M02 vs C94800-TF00 — frequently asked

Is C94800-TF00 stronger than C94800-M02?

Yes. C94800-TF00 has a typical yield strength of 275 MPa (39.9 ksi) against 170 MPa (24.7 ksi) for C94800-M02 — about 62% more. Tensile strength is 415 MPa (60.2 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, M02 or TF00?

M01 is the default C94800 condition in the FabDigit quote flow (neither M02 nor TF00). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C94800-M02 or C94800-TF00?

C94800-M02. Its machinability rates very good (80/100) against good (60/100) for C94800-TF00; for welding the order is C94800-M02 first (poor, 30/100) then C94800-TF00 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C94800-M02 and C94800-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.